Siemens ADVANCE NETWORK COMMUNICATIONS BOARD/DATANET 20005 User Manual Page 51

  • Download
  • Add to my manuals
  • Print
  • Page
    / 72
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 50
Command Descriptions, Continued
local> list 155
msg | source | destination | size | source port | time stamp
155 | Trace enabled | 00:01:48.23
156 | IP-172.16.9.211 | IP-172.16.9.210 | 64 | 2 | 00:01:48.29
157 | IP-172.16.9.211 | IP-172.16.9.210 | 64 | 2 | 00:01:49.00
158 | IP-172.16.9.210 | IP-172.16.9.211 | 64 | Ethernet | 00:01:49.75
159 | IP-172.16.9.211 | IP-172.16.9.210 | 64 | 2 | 00:01:50.11
160 | Station detected IP-172.16.9.014 | 00:02:00.00
161 | IP-172.16.9.014 | IP-172.16.9.210 | 1536 | 5 | 00:02:18.29
162 | IP-172.16.9.211 | IP-172.16.9.210 | 1536 | 2 | 00:02:18.00
163 | IP-172.16.9.210 | IP-172.16.9.211 | 1132 | Ethernet | 00:02:19.75
164 | IP-172.16.9.211 | IP-172.16.9.210 | 64 | 2 | 00:02:20.11
The event display gives a time-stamp, and an event description. All
events other than frame-capture events are always shown as single
lines. Captured frames may be summarized as single lines, or expanded
into a multi-line display.
Time stamps are shown as elapsed time from the last board reset or
power-on.
The user can view more than 22 messages by supplying at sequence
number and list length:
list 1, 300 List message numbers 1 – 300.
The list length may appear by itself:
list , 32
This lists the next 32 trace buffer entries and increments the current
message number by 32.
All the messages in the internal trace buffer can be viewed by listing
sequence number one then entering the list command until the last
message is displayed. When the current message number is
incremented to the last message in the internal buffer, it is automatically
set to 1.
There is a continuous listing mode for monitoring all the messages in the
internal trace buffer. It is set by entering list on. All the messages in the
internal buffer will be displayed and any new messages will be listed as
soon as they are collected into the buffer. Hitting any key terminates the
continuous listing mode.
To clear all events from the event buffer, use
list clear
2000592-001 Command Summary 41
Page view 50
1 2 ... 46 47 48 49 50 51 52 53 54 55 56 ... 71 72

Comments to this Manuals

No comments