Communications Confidential 1 COM MD CC GRM T J. Junggebauer Version 1.0 July 2005 Repair Manual Gigaset C350, C355 up to level 2.5
Communications Confidential 10 COM MD CC GRM T J. Junggebauer Version 1.0 July 2005 RD CP 1 04 06 03/ SP LEDSENDEE PROM8 KByte H
Communications Confidential 11 COM MD CC GRM T J. Junggebauer Version 1.0 July 2005 Infinineon TLE4308 und IFX1117GSV succession LDO_1.8
Communications Confidential 12 COM MD CC GRM T J. Junggebauer Version 1.0 July 2005 5.3 Block diagram C355 base station VEGA Bluebird Step
Communications Confidential 13 COM MD CC GRM T J. Junggebauer Version 1.0 July 2005 6 Repair of handset ESD regulations have to be follow
Communications Confidential 14 COM MD CC GRM T J. Junggebauer Version 1.0 July 2005 6.2 Disassembling of handset 1. alternative (recomme
Communications Confidential 15 COM MD CC GRM T J. Junggebauer Version 1.0 July 2005 Insert the opening tool G2000/ 4000 between both case s
Communications Confidential 16 COM MD CC GRM T J. Junggebauer Version 1.0 July 2005 Open the last 2 latches in the battery
Communications Confidential 17 COM MD CC GRM T J. Junggebauer Version 1.0 July 2005 6.3 Assembling of handset The assembling procedure of
Communications Confidential 18 COM MD CC GRM T J. Junggebauer Version 1.0 July 2005 6.5 Board Layout of handset
Communications Confidential 19 COM MD CC GRM T J. Junggebauer Version 1.0 July 2005 Via 6.6 Humidity or liquid damage Diagnosis code IRIS
Communications Confidential 2 COM MD CC GRM T J. Junggebauer Version 1.0 July 2005 1 Table of contents 1 TABLE OF CONTENTS ...
Communications Confidential 20 COM MD CC GRM T J. Junggebauer Version 1.0 July 2005 6.7 Earphone capsule/ receiver faulty Affected unit:
Communications Confidential 21 COM MD CC GRM T J. Junggebauer Version 1.0 July 2005 6.8 Loudspeaker faulty Affected unit: Handset Diagn
Communications Confidential 22 COM MD CC GRM T J. Junggebauer Version 1.0 July 2005 (1)(2) 6.9 Display cover broken or scratched Affected
Communications Confidential 23 COM MD CC GRM T J. Junggebauer Version 1.0 July 2005 6.10 Display module faulty Affected unit: Handset
Communications Confidential 24 COM MD CC GRM T J. Junggebauer Version 1.0 July 2005 Put some flux on the pads and resolder them until the s
Communications Confidential 25 COM MD CC GRM T J. Junggebauer Version 1.0 July 2005 Align the display foil on the PCB and fix it. Put s
Communications Confidential 26 COM MD CC GRM T J. Junggebauer Version 1.0 July 2005 Put the soldering tip FP7 on the soldering iron and sol
Communications Confidential 27 COM MD CC GRM T J. Junggebauer Version 1.0 July 2005 Fix the display foil with a finger and gently remove th
Communications Confidential 28 COM MD CC GRM T J. Junggebauer Version 1.0 July 2005 6.11 Microphone faulty Affected unit: Handset Diagn
Communications Confidential 29 COM MD CC GRM T J. Junggebauer Version 1.0 July 2005 7 Repair of basestation The procedures are absolutely
Communications Confidential 3 COM MD CC GRM T J. Junggebauer Version 1.0 July 2005 2 Procedures Since the C350/ 355 is a C340/ C345 in a P
Communications Confidential 30 COM MD CC GRM T J. Junggebauer Version 1.0 July 2005 Open the housing as described on the picture below.
Communications Confidential 31 COM MD CC GRM T J. Junggebauer Version 1.0 July 2005 7.2 Disassembling C355 Needed material: suitable screw
Communications Confidential 32 COM MD CC GRM T J. Junggebauer Version 1.0 July 2005 7.4 Exploded view C350/ C340
Communications Confidential 33 COM MD CC GRM T J. Junggebauer Version 1.0 July 2005 7.5 Exploded view C355/ C345
Communications Confidential 34 COM MD CC GRM T J. Junggebauer Version 1.0 July 2005 7.6 Board Layout C350
Communications Confidential 35 COM MD CC GRM T J. Junggebauer Version 1.0 July 2005 7.7 Board Layout C355
Communications Confidential 36 COM MD CC GRM T J. Junggebauer Version 1.0 July 2005 7.8 Lightning stroke damage Diagnosis code IRIS: 62
Communications Confidential 37 COM MD CC GRM T J. Junggebauer Version 1.0 July 2005 7.9 Loudspeaker faulty Affected unit: Gigaset C355
Communications Confidential 38 COM MD CC GRM T J. Junggebauer Version 1.0 July 2005 7.10 Charging problems Affected unit: Gigaset C350,
Communications Confidential 39 COM MD CC GRM T J. Junggebauer Version 1.0 July 2005 7.11 Line seizure problems Affected unit: Gigaset C
Communications Confidential 4 COM MD CC GRM T J. Junggebauer Version 1.0 July 2005 2.2 Service procedures for Gigaset C 350 and 355 Press
Communications Confidential 40 COM MD CC GRM T J. Junggebauer Version 1.0 July 2005 Repair: Desolder the IC and solder a new component with
Communications Confidential 5 COM MD CC GRM T J. Junggebauer Version 1.0 July 2005 * Read customer settings (menu, 54918): Menu for Hotlin
Communications Confidential 6 COM MD CC GRM T J. Junggebauer Version 1.0 July 2005 3 Lasered imprint and sticker on microprocessor T
Communications Confidential 7 COM MD CC GRM T J. Junggebauer Version 1.0 July 2005 4 Test and identification of faulty component Not all
Communications Confidential 8 COM MD CC GRM T J. Junggebauer Version 1.0 July 2005 4.1 Check of complete system with fault description of
Communications Confidential 9 COM MD CC GRM T J. Junggebauer Version 1.0 July 2005 4.5 Functional Test There is an incoming and an outgoin
Comments to this Manuals