Page view 77
EMCO WINNC SINUMERIK 810/820 T ALARMS / MESSAGES
H 2
0037 Memory allocation failure
Remedy: Close all other WINDOWS applications or
restart WINDOWS.
0038 Unauthorized software version
Contact EMCO.
0039 Project data non compatible to software
version
Possible error after updates, contact EMCO.
0040 Invalid entry for DNC interface in the
profile ...
Cause: The DNC entry in the file project.ini is
invalid.
Remedy: Setting with WinConfig
0100 Mailslot could not be created
Cause: Insufficient memory in the memory area
below 640 kB.
Remedy: Close all other applications, restart
WINDOWS. If this is not successfull,
remove not necessary device and drivers
entries in config.sys or load them in the
upper memory area.
0101 For WinCTS Windows for Workgroups
3.11 or higher is required
WinCTS requires WINDOWS for WORKGROUPS
version 3.11 or higher.
0102 Error creating the reference table for
keybitmaps
Remedy: Restart WINDOWS. If this alarm occurs
repeatedly, contact EMCO.
0103 Invalid entry for WinCTS status in the
profile ...
Cause: The CTS entry in the file project.ini is
invalid.
Remedy: Contact EMCO
0104 Error getting the workgroup name
Remedy: Restart WINDOWS. If this alarm occurs
repeatedly, contact EMCO.
0105 No workgroup found
Remedy: Insert the computer into the workgroup for
WinCTS, if necessary set up a workgroup
for the WinCTS computers.
0106 Invalid entry for the number of keys to
record in the profile ...
Cause: The KeyFifoSize entry in the file winnc.ini
is invalid.
Remedy: Correct the number, e.g. 50(see
WinConfig).
0107 - 0110 (various alarms)
Remedy: Restart WINDOWS. If this alarm occurs
repeatedly, contact EMCO.
Control Alarms
These alarms can occur only with operating and
programming the control functions or with running
CNC programs.
16 Parity error (RS232)
Cause: data I/O: data transmition error character
overflow
Remedy: set same parity for sender and receiver
17 Overflow error (RS232)
Cause: data I/O: data transmition error parity
18 Frame error (RS232)
Cause: data I/O: data transmition error data frame
Remedy: ev. set same configuration for both RS232
30 PP memory overflow (RS232)
Cause: data I/O: unknown data type, error data
32 Data format error (RS232)
Cause: data I/O: error while opening file
1040 ORDxx DAC limit X
Cause: step motor in X felt out of pace
Remedy: e.g. select lower feed or chip cross section,
check slides for smooth running, approach
reference point
1041 ORDxx DAC limit Y
see alarm 1040
1042 ORDxx DAC limit Z
see alarm 1040
1480 ORDxx SW overtravel switch X
Cause: software end switch in X overtravelled
Remedy: traverse back manually
1481 ORDxx SW overtravel switch Y
see alarm 1480
1482 ORDxx SW overtravel switch Z
see alarm 1480
1560 Nxxxx Set speed to high/low
Cause: too high/low S-value
Remedy: correct program, enter belt gage in setting
data
2040 Block not in memory
Cause: Block search target not found
Remedy: correct program
2041 CNC program not foand
Cause: NC Program (subroutine, contour routine)
not found; with NC start no program was
selected
Remedy: correct call up or create program