Siemens RDF300…/RDF340.../RDF400… Room Temperature Controllers N3076en
Building Technologies 11 July 2008
Use
To control the room temperature in individual rooms and zones that are:
Heated or cooled with 2-pipe fan coil units
Heated or cooled with 2-pipe fan coil units with electrical heater
Heated and cooled with 4-pipe fan coil units
Heated or cooled with compressor in DX-type equipment
Heated or cooled with compressor in DX-type equipment with electrical heater
Heated and cooled with compressor in DX-type equipment
The RDF300…/RDF400… controls:
One single or 3-speed fan
One or two on/off valve actuators
One on/off valve actuator and one 1-stage electrical heater
One 3-position valve actuator
One 1-stage compressor in DX-type equipment or one 1-stage compressor with
electrical heater
The RDF340… controls:
One single or 3-speed fan
One or two DC 0…10 V valve actuators
One DC 0…10 V valve actuator and one modulating electrical heater (DC 0…10 V)
Use in systems with:
Heating or cooling mode
Automatic heating/cooling changeover
Manual heating/cooling changeover
Heating and cooling mode (e.g. 4-pipe system)
Functions
Maintain room temperature via built-in temperature sensor or external room
temperature / return air temperature sensor
Automatic or manual changeover between heating and cooling mode
Select applications via DIP switches
Select operating mode via the operating mode button on the controller
Single or 3-speed fan control (automatic or manual)
Display current room temperature or setpoint in °C and/or °F
Minimum and maximum setpoint limitation
Keypad lock (automatic and manual)
Two multifunctional inputs, freely selectable for:
Operating mode switchover contact (key card)
Automatic heating/cooling changeover sensor
External room temperature or return air temperature
Dewpoint sensor
Electrical heater enable
Alarm input
Advanced fan control function, i.e. fan kick, fan start, selectable fan operation
(enable, disable or depending on heating or cooling mode)
Purge function together with 2-port valve in a 2-pipe changeover system
Reminder to clean filters
Floor heating temperature limit
Reload factory settings for commissioning and control parameters
Weekly time program: 8 programmable timers to switch over between Comfort and
Economy mode (RDF400.01)
Optional backlit LCD (RDF300.02/RDF400.01)
Optional infrared remote control ( RDF400.01)