N3076en
11 July 2008
Building Technologies
3
076
RDF300, RDF300.02, RDF340 RDF400.01
Semi Flush-mount
Room Temperature
Controllers with LCD
RDF300…
RDF340…
RDF400…
for 2-pipe, 2-pipe with el. heater and 4-pipe fan coil units
for use with compressors in DX type equipment
RDF300/RDF400 AC 230 V operating voltage, on/off or
3-position control outputs
RDF340… AC 24 V operating voltage, DC 0…10 V control outputs
Output for 3-speed or 1-speed fan
Two multifunctional inputs for keycard contact, external sensor, etc.
Operating modes: Comfort, Energy Saving and Protection
Automatic or manual heating/cooling changeover
Adjustable commissioning and control parameters
Minimum and maximum setpoint limitation
Mounting on recessed rectangular conduit box, 60.3 mm fixing centers
Additional RDF300.02 features
Backlit LCD
Additional RDF400.01 features
Backlit LCD
Infrared remote control receiver
Auto Timer mode with 8 programmable timers
Page view 0
1 2 3 4 5 6 7 8 9 10

Summary of Contents

Page 1 - Building Technologies

N3076en 11 July 2008 Building Technologies 3076 RDF300, RDF300.02, RDF340 RDF400.01 Semi Flush-mount Room Temperature Controllers

Page 2

10/10 Siemens RDF300…/RDF340.../RDF400… Room Temperature Controllers N3076en Building Technologies 11 July 2008 Dimensions Dimensions in mm

Page 3 - 2) Not available in EU

2/10 Siemens RDF300…/RDF340.../RDF400… Room Temperature Controllers N3076en Building Technologies 11 July 2008 Use To control the room temperat

Page 4

3/10 Siemens RDF300…/RDF340.../RDF400… Room Temperature Controllers N3076en Building Technologies 11 July 2008 Applications The controller supp

Page 5

4/10 Siemens RDF300…/RDF340.../RDF400… Room Temperature Controllers N3076en Building Technologies 11 July 2008 Equipment combinations Type of

Page 6

5/10 Siemens RDF300…/RDF340.../RDF400… Room Temperature Controllers N3076en Building Technologies 11 July 2008 Mechanical design The controller

Page 7

6/10 Siemens RDF300…/RDF340.../RDF400… Room Temperature Controllers N3076en Building Technologies 11 July 2008 Mounting and installation Mount

Page 8

7/10 Siemens RDF300…/RDF340.../RDF400… Room Temperature Controllers N3076en Building Technologies 11 July 2008 Disposal The device is classifi

Page 9 - AC 230 V

8/10 Siemens RDF300…/RDF340.../RDF400… Room Temperature Controllers N3076en Building Technologies 11 July 2008 Operation Climatic conditions Te

Page 10

9/10 Siemens RDF300…/RDF340.../RDF400… Room Temperature Controllers N3076en Building Technologies 11 July 2008 Connection terminals LX1MNQ1 Q2

Comments to this Manuals

No comments