MC55 AT Command Set
16.15 AT^SNFS
s
m
obil
e
MC55_ATC_V01.05 Page 415 of 469 2/10/04
Confidential / Released
Examples
EXAMPLE 1
Suppose a user wishes to use alternatively a handsfree device and a handset. The handset can be connected
to the first analog interface and adjusted to audio mode 4. The handsfree device can be attached to the sec-
ond analog interface and adjusted to audio mode 2. The factory defaults of
AT^SAIC need not be changed.
Settings for the handset:
Settings for the handsfree device:
To store the configuration to the user defined audio profile:
To switch back and forth:
EXAMPLE 2
The following example illustrates a combination of a handset and a handsfree device connected to other inter-
faces than those assumed as factory default.
Settings for a handset connected to the second analog interface and adjusted to audio mode 4:
AT^SNFS=4
OK
AT^SAIC?
Factory default of AT^SAIC assigned to audio mode 4.
^SAIC: 2,1,1
OK
AT^SNFS=2
OK
AT^SAIC?
Factory default of AT^SAIC assigned to audio mode 2.
^SAIC: 2,2,2
OK
AT^SNFW
Stores the audio mode and the interface.
OK
AT^SNFS=4
Switches to the handset connected to analog interface 1.
OK
AT^SNFS=2
Switches to the handsfree device at analog interface 2.
OK
AT^SNFS=4
OK
AT^SAIC=2,2,2
OK