MC55 AT Command Set
8.8 AT^SMONG
s
m
obil
e
MC55_ATC_V01.05 Page 204 of 469 2/10/04
Confidential / Released
Display period in seconds
If
<period> is omitted the cell data will be presented only once on a single line (as if Execute command was
issued).
If
<period> is given, the cell data will be listed repeatedly on 10 data lines. Every 10
th
data line is followed by
the header, simply to repeat the column titles.
1...100
Note
For compatibility with earlier products and to support legacy applications, often any input character will stop
the periodic output of the write command. But since this applies only in certain cases (depending on the set-
tings of Chapter 4.7, page 96 and Chapter 4.8, page 99), it is recommended to always use "at" or "AT".
8.8.1 AT^SMONG Cell Info Table
Example output for AT^SMONG:
Columns of the cell info table:
<period>
(num)
GPRS Monitor
BCCH G PBCCH PAT MCC MNC NOM TA RAC # Cell #
0637 1 - 4 234 05 2 00 0B
Column Description
BCCH ARFCN of BCCH carrier
G GPRS supported (''1'') or not supported ''-''
PBCCH If PBCCH is present, indication of ARFCN, else ''-'' or if Frequency Hopping is used ''H''
PAT Priority Access Threshold (GSM Rec. 04.08 / 10.5.2.37b)
0 Packet access is not allowed in the cell
1 Spare, shall be interpreted as "000" (packet access not allowed)
2 Spare, shall be interpreted as "000" (packet access not allowed)
3 Packet access is allowed for priority level 1
4 Packet access is allowed for priority level 1 to 2
MCC Mobile Country Code
MNC Mobile Network Code
NOM Network Operation Mode (1...3)
TA Timing Advance Value
RAC Routing Area Code (as hexadecimal value)