Siemens SPCK422 User Manual Page 17

  • Download
  • Add to my manuals
  • Print
  • Page
    / 20
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 16
17
Expanders
SPCE650.100
Expander, 8
Inp./2 Outp.
SPCE450.100
Expander, 8
Relay-Outputs
SPCA210.100
2-Door Expander
SPCW130.100
SiWay RF-
Expander
SPCE120.100
Indication
Expander
SPCE110.100
Key Switch
Expander
LED indicators
4 outputs
(void/valid for
each reader)
16 tri-color LEDs,
freely
programmable
2 tri-color LEDs,
freely
programmable
Special keys
4 function keys,
freely
programmable
Operating voltage 9.5  14 V DC 9.5  14 V DC 9.5  14 V DC 9.5  14 V DC 9.5  14 V DC 9.5  14 V DC
Field bus
1)
X-BUS on RS-485
(307 kb/s)
X-BUS on RS-485
(307 kb/s)
X-BUS on RS-485
(307 kb/s)
X-BUS on RS-485
(307 kb/s)
X-BUS on RS-485
(307 kb/s)
X-BUS on RS-485
(307 kb/s)
Tamper contact
On-board front
spring tamper
On-board front
spring tamper
On-board front
spring tamper
On-board front
spring tamper
On-board front /
back tamper
switch
On-board front /
back tamper
switch
Operating
temperature
-10 °C to 50 °C -10 °C to 50 °C -10 °C to 50 °C -10 °C to 50 °C -10 °C to 50 °C -10 °C to 50 °C
Relative humidity
Max. 90 %
(non-condensing)
Max. 90 %
(non-condensing)
Max. 90 %
(non-condensing)
Max. 90 %
(non-condensing)
Max. 90 %
(non-condensing)
Max. 90 %
(non-condensing)
Color
RAL 9003
(signal white)
RAL 9003
(signal white)
RAL 9003
(signal white)
RAL 9003
(signal white)
RAL 9003
(signal white)
RAL 9003
(signal white)
Housing
Plastic enclosure
(ABS)
Plastic enclosure
(ABS)
Plastic enclosure
(ABS)
Plastic enclosure
(ABS)
Plastic enclosure
(Polycarbonate)
Plastic enclosure
(Polycarbonate)
Dimensions
(W x H x D in mm)
200 x 153 x 47
(Enclosure)
150 x 82 x 20
(PCB)
200 x 153 x 47
(Enclosure)
150 x 82 x 20
(PCB)
200 x 153 x 47
(Enclosure)
150 x 82 x 20
(PCB)
200 x 153 x 47
(Enclosure)
150 x 82 x 20
(PCB)
112 x 92 x 28 112 x 92 x 38
Weight 0.35 kg 0.40 kg 0.36 kg 0.34 kg 0.19 kg 0.27 kg
Operating current
Max. 80 mA at
12 V DC (all relays
operated)
Max. 190 mA at
12 V DC (all relays
operated)
Max. 80 mA
at 12 V DC (all
relays operated)
Max.60 mA at
12 V DC
Max. 70 mA at
12 V DC (all LEDs
operated)
Max. 50 mA at
12 V DC (relay
and LEDs
operated)
Quiescent current
Min. 40 mA at
12 V DC
Min. 40 mA at
12 V DC)
Min. 45 mA at
12 V DC
Min. 60 mA at
12 V DC
Min. 30 mA at
12 V DC
Min. 30 mA at
12 V DC
Card reader
Integrated
125 kHz reader
(EM 4102)
Radio Module
Integrated SiWay
RF receiver
(868 MHz)
Number of on-board
zones
8, freely
programmable
4, for door release
switch (DRS) and
door position
switch (DPS), or
freely
programmable
1, freely
programmable
EOL resistor
Dual 4K7
(default), other
resistor
combinations
configurable
Dual 4K7
(default), other
resistor
combinations
configurable
Dual 4K7
(default), other
resistor
combinations
configurable
Number of on-board
relays
2, freely
programmable
(single-pole
changeover,
30 V DC / max.
1 A)
8, freely
programmable
(single-pole
changeover,
30 V DC / max.
1 A)
2, for door lock or
freely
programmable
(single-pole
changeover,
30 V DC / max.
1 A)
1, freely
programmable
(single-pole
changeover,
30 V DC /
max. 1 A)
Programmable key
input
3 key positions (2-
0-1 in 90° steps,
cylinder type
KABA1008C)
Number of card
readers
2
Card reader protocols
Wiegand 26 bits
(standard),
Clock&Data and
Wiegand 36-bit
(proprietary)
1)
Max. 400 m between devices in chain configuration / cable types IYSTY 2 x 2 x Ø 0.6 mm (min.), UTP cat5 (solid core) or Belden 9829.