Technical data
Controller
SPC5230.310-L1
Intrusion CP, G3
SPC5320.310-L1
Intrusion CP, G2
SPC5330.310-L1
Intrusion CP, G3
SPCP332.300
Smart PSU (7 Ah)
with I/O- Expander
SPCP333.300
Smart PSU (17 Ah)
with I/O- Expander
Number of on-board zones 8, freely programmable 8, freely programmable
EOL resistor Dual 4K7 (default), other resistor combinations configurable
Dual 4K7 (default), other resistor combinations
configurable
Max. number of hardwired zones 128
Max. number of wireless zones
1)
120
Number of on-board open coll.
2, for internal / external bell (max. 400 mA each)
3, freely programmable
(max. 400 mA each, supplied via auxiliary output)
Number of on-board relays 1, for strobe (single-pole changeover, 30 V / max. 1 A)
2, freely programmable
(single-pole changeover, 30 V DC / max. 1 A)
Max. number of outputs 128
Programmable areas 16
Max. number of user codes 256
Intrusion Event Logs 10000 log events shared across all areas
Access Event Logs 10000 log events
Field bus
2)
X-BUS on RS-485 (307 kb/s) X-BUS on RS-485 (307 kb/s)
Number of field devices
3)
48 (16 Keypads, 16 Door-expanders,
16 Input/Output expanders)
Connectable field devices
Keypads: SPCK42x, SPCK63x
Door Expanders: SPCA21x
Input/Output Expanders: SPCE65x, SPCE45x, SPCP33x, SPCE11x,
SPCE12x
Tamper contact
On-board front cabinet spring tamper
+ 2 auxiliary tamper inputs
Front cabinet spring
tamper
Front cabinet spring
tamper / back tamper
2 X-BUS (2 spurs or 1 loop)
2 RS232 (RJ45 ports, for X-10 or external communication)
1 USB (PC for browser programming / terminal program)
1 Fast Programmer
Interfaces
1 Ethernet (RJ45) 1 Ethernet (RJ45)
Power supply Type A (per EN50131-1), Integrated on controller PCB Type A (per EN50131-1)
Input voltage 230 V AC, +10 to -15 %, 50 Hz at transformer 230 V AC, +10 to -15 %, 50 Hz at transformer
Operating current max. 160 mA max. 200 mA max. 200 mA
Max. 95 mA
(all relays activated)
Max. 95 mA
(all relays activated)
Quiescent current
Controller 140 mA
- with single PSTN:
165 mA
- with single GSM:
270 mA
- with PSTN &
GSM: 295 mA
Controller 170 mA
- with single PSTN:
195 mA
- with single GSM:
300 mA
- with PSTN &
GSM: 325 mA
Controller 170 mA
- with single PSTN:
195 mA
- with single GSM:
300 mA
- with PSTN &
GSM: 325 mA
Min. 77 mA Min. 77 mA
Auxiliary power (nominal)
Max. 750 mA
(subject to size of battery fitted & Security Grade required)
Max. 2 x 750 mA (subject to size of battery
fitted & Security Grade required)
Output voltage
11-14 V DC in normal conditions
(mains powered and fully charged battery)
4)
11-14 V DC in normal conditions
(mains powered and fully charged battery)
4)
Max.24 hours 72 hours Max. 24 hours Max. 72 hours Max. 24 hours
Battery charger
to recharge battery to 80% (YUASA battery) to recharge battery to 80% (YUASA battery)
Battery capacity
Max. 17 Ah / 12 V
(Battery optional)
Max. 7 Ah / 12 V
(Battery optional)
Max. 17 Ah / 12 V
(Battery optional)
Max. 7 Ah / 12 V
(Battery optional)
Max. 17 Ah / 12 V
(Battery optional)
Hinged metal
enclosure
Small metal
enclosure
Hinged metal
enclosure
Small metal
enclosure
Hinged metal
enclosure
Housing
1.4 mm mild steel 1.4 mm mild steel
Dimensions (W x H x D in mm) 326 x 415 x 114 264 x 357 x 81 326 x 415 x 114 264 x 357 x 81 326 x 415 x 114
Weight 7.30 kg 4.60 kg 7.30 kg 5.20 kg 7.40 kg
Colour RAL 9003 (signal white) RAL 9003 (signal white)
Operating temperature -10 to +50 °C -10 to +50 °C
Relative humidity Max. 90 % (non-condensing) Max. 90 % (non-condensing)
Standards
5)
Designed to meet
EN50131-1:2006
(Grade 3, Class II
Indoor General),
TS50131-3:2003,
EN50131-6:2008
Designed to meet
EN50131-1:2006
(Grade 2, Class II
Indoor General),
TS50131-3:2003,
EN50131-6:2008
Designed to meet
EN50131-1:2006
(Grade 3, Class II
Indoor General),
TS50131-3:2003,
EN50131-6:2008
1)
A wireless zone takes away a wired zone / optional RF receivers required.
2)
More I/O expanders can be addressed instead of a keypad or door expander, but number of programmable inputs / outputs cannot exceed specified system limits.
3)
Max. 400 m between devices in chain configuration / cable types IYSTY 2 x 2 x Ø 0.6 mm (min.), UTP cat5 (solid core) or Belden 9829.
4)
When the secondary device is powering the auxiliary output, voltages as low 9.5 V can be seen on this output before the system shuts down to deep discharge protection.
5)
Refer to the installation instructions of the specific devices for approval details and local approvals.