Technical fearures
SPC5230.310-L1 SPC5320.310-L1 SPC5330.310-L1
INTRUSION
Programmable areas 16
Number of on-board zones 8
Max. number of hardwired zones 128
Supervised input No EOL / Single EOL / Dual EOL / Tri EOL (Antimask PIR) / Inertial Sensors
EOL resistor 4K7 (default), other resistor combinations configurable
Number of on-board outputs 6
Max. number of outputs 128
Max. number of user codes 256
Event memory 10000 intrusion events
Calendar based time channels 32 (53-week calendar)
Cause & Effects 256 triggers / 128 mapping gates
Language Multi-language support
Voice assistance Supported
Customer Logo Supported
FIELD BUS
Bus connections X-BUS (2 spurs or 1 loop)
Number of field devices
1)
48 (16 Keypads, 16 Door-expanders, 16 Input/Output expanders)
CONNECTIVITY
Web Server HTTPS (embedded)
Pluggable Communication Interfaces PSTN or GSM/GPRS modem (system supports 2 optional modems simultaneously)
Standard Communication Protocol SIA, Contact ID, Scancom Fast Format, SMS messaging
Fast Programmer Support Yes
Firmware Upgrade Local / Remote upgrade for Controller and Expanders
SMS event notification / Panel control With GSM option
Local and Remote configuration (SPC Pro
support)
Via RS232, USB, PSTN, GSM
Via RS232, USB, PSTN, GSM,
IP over Ethernet
Via RS232, USB, PSTN, GSM,
IP over Ethernet
Automated Remote Maintenance (SPC RM
support)
Via PSTN, GSM
Via PSTN, GSM,
IP over Ethernet
Via PSTN, GSM,
IP over Ethernet
Automated Site Administration (SPC Safe
support)
Via IP over Ethernet Via IP over Ethernet
IP Alarm and Event transmission
(SPC Com support)
IP over Ethernet / GPRS IP over Ethernet / GPRS
X-10 Support of X-10 Power Controller and X-10 commands
ACCESS
Event memory 10000 access events
Max. number of doors (entry / entry-exit) 16 / 16
Max. number of door groups 16
Support of readers with card and/or PIN Yes
Supported card technologies EM4102 / SiPass, Wiegand 26-bits, HID Corporate 1000
Pass-back prevention (soft / hard) Yes
Custodian for door groups Yes
Escort through doors Yes
WIRELESS
Max. number of wireless zones
2)
120
Max. number of wireless remote controls 256
Max. number of Intrunet wireless detectors
received by any wireless receiver
(recommended)
20
1)
More I/O expanders can be addressed instead of a keypad or door expander, but number of programmable inputs / outputs cannot exceed specified system limits.
2)
A wireless zone takes away a wired zone / optional RF receivers required.