5 18µH Coil
5.1 Affected Units
5.1.1 Type: C25
5.1.2 Affected IMEIs / Date Codes: All / All
5.1.3 Affected SW-Versions: All
5.1.4 Fault Code for LSO reporting: 3COI
5.2 Fault Description
5.2.1 Fault Symptoms for customers:
Loud humming noise in loudspeaker.
5.2.2 Fault Symptom on GSM-Tester:
Handset fails with loud humming noise in echo loop.
5.3 Priority: