67
HINT: Because the flow
switch only closes when
water is flowing, the heater
resistance can only be
measured at the heater
terminals (not at the control
module).
HINT: The NTC and
High Limit are contained
in the same part. When
either fails, replace
entire part # 165281.
Use dishwasher test
program to turn on
heater, then measure
dishwasher incoming
current. If ~ 1.5A,
heater, Hi-Limit, flow
switch or circulation
pump has failed.
Check voltage @
module (or timer) -- if
0V, module (or timer)
has failed.
For electronic models,
current can also be
measured through
red heater
wire at
control module (~
9.5A). Since there
can be more than one
red wire, check wiring
diagram to select
heater wire.
NOTE: Open door to run test
program for fully-integrated models.
NOTE: Flow through heaters heat
water ~ 2ºF / minute.