Siemens NCZ Specifications Page 94

  • Download
  • Add to my manuals
  • Print
  • Page
    / 120
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 93
7-94
Copyright © Siemens AG 2006
SINUMERIK 810D Equipment Manual Configuration CCU (PHC) – 03/2006 Edition
+5 V monitoring
Temperature monitoring 60
C "3
C
Configuration monitoring
Sign-of-life monitoring (watchdog) of the microcontroller
Sign-of-life monitoring of the NC
Fault Acquisition Effect
Undervoltage
(< 4.75 V)
Limit monitor Disabling of the NC outputs,
LED (green) off
Ambient temperature Temperature sensor Status signal to NC,
screen display
Sign of life CCU Cyclic signaling Disabling of the NC outputs,
LED (red) on
Watchdog Time acquisition Disabling of the NC outputs,
LED (red) on
Hardware combination Hardware
configuration
Disabling of the NC outputs,
LED (red, yellow) on,
status signal to NC
The digital and analog ouputs are switched to a safe state (0 V at the output)
with the XOUTDS signal in the event of disturbances or faults in the CCU, the
microcontroller, and power failure.
DC 24 V (20.4 V DC to 28.8 V DC)
Connector designation: X9
Connector type: 4-pole terminal block, 2.5 mm
2
Terminal
Table 7-1 X9 pin assignments
X9
Pin Name Type
1 P24 ext VI
2 P24 ext VI
3 M24 ext VI
4 M24 ext VI
Note
Pins 1 and 2 or 3 and 4 are bridged in a group on the module.
Signal names
P24 ext +24 V power supply external
M24 ext Power supply ground external
Signal type
VI Voltage Input
Monitoring
functions
Power supply
7 NCU Terminal Block
Page view 93