TC12 Installation, Commissioning & Maintenance Handbook
666/HE/43100/000 Page 84 Issue 10
Number of Current Sensors
Number of phases (include vehicle, green arrow and pedestrian
phases
+___
Number of pedestrian phases with wait indicators
+___
Number of switched sign drives
+___
Number of separately monitored regulatory sign drives
+___
Add one for each monitored load above 4A rms
+___
Subtract one for each wait indicator to be monitored by the same
current sensor as the pedestrian phase
+___
Subtract one for each pedestrian phase to be monitored by the same
current sensor as the opposing vehicle phase
+___
Total current sensors
=___
Number of Voltage Sensors
Number of phases (include vehicle, green arrow and pedestrian
phases
+___
Number of pedestrian phases with wait indicators
+___
Number of switched sign drives.
+___
Subtract one for each phase green state which coincides with a green
confirm reply available from the controller
Note: This is only applicable where Red Lamp Monitoring is not
required.
+___
Subtract one for each wait indicator state that coincides with a wait
confirm reply available from the controller
+___
Add one for each vehicle phase with Red Lamp Monitoring
+___
For export lamp monitoring only:
Add one where the controller can enter flashing red/amber mode
Note: Not needed if a signal indicating flash mode active is available
from the controller.
+___
Add one for each flashing amber signal group
+___
Total voltage sensors
=___