666/HE/43100/000 Page 74 Issue 10
Figure 26 - Outstation Output Connections
OUTSTATION PROCESSOR PCB - PL4
34-way connector to Relay Outputs.
PIN NAME
1
2
Output 1
3
4
Output 2
5
6
Output 3
7
8
Output 4
9
10
Output 5
11
12
Output 6
13
14
Output 7
15
16
Output 8
17
18
Output 9
19
20
Output 10
21
22
Output 11
23
24
Output 12
25
26
Output 13
27
28
Output 14
29
30
Output 15
31
32
Output 16
33
34
Transmit Confirm Relay Output
3.2.3.6 Connection of SCOOT Detector Inputs to Free-Standing TC12 OTU
On a free-standing TC12 OTU, the SCOOT detector inputs to the OTU should be
connected to the normally closed contacts on the detector backplane. On an STC
detector back plane these are the odd numbered pins starting at pin 9.