Installation
Hot Alignment
It is possible for the motor shaft height to change
relative to the driven equipment and this should be
compensated for during the alignment procedure.
Heat from driven equipment can also cause horizontal
misalignment.
WARNING
Rotating parts.
Can cause serious injury.
Disconnect and lock out power before working on
equipment.
If motor application is abnormal (high temperature,
extreme vibration, etc.) consult the factory for special
instructions or additional information.
Check for vertical alignment (parallelism) of coupled
drive as follows:
1. Operate unit until normal temperature is reached
(may require several hours).
2. Shut down motor and lock out switch.
3. Mount dial indicator as in Figure 2.
4. Rotate shaft, noting readings at 0°, 90°, 180°, and
270° (both sides, top, and bottom). If within 0.002
inch total indicator reading, or other limit specified
by the factory, unit is satisfactory for operation.
5. If not within limits, add or remove shims as
required to raise or lower motor.
6. If shims are changed for high temperature
operation, repeat alignment procedure to extent
necessary to assure proper alignment. Document
readings for warranty information.
Vibration
The standard unfiltered housing vibration limits
measured at no load, uncoupled, and with rigid
mounting are as follows based on the requirements of
NEMA MG1-7.8.
Speed
Velocity, inches/sec peak
1200 3600 RPM
0.120
1000 RPM
0.105
900 RPM
0.096
750 RPM
0.079
720 RPM
0.075
600 RPM
0.063
After alignment is complete and foot mounting bolts are
tight, run motor at no load (or minimum possible).
Check for vibration. If excessive vibration exists and
the alignment is acceptable, check foot plane by
loosening one drive end-mounting bolt at a time as
detailed below. This is to be documented for warranty
information. When resiliently mounted, allowed levels
are 25% higher.
Base or foundation rigidity can also affect vibration;
check for resonance in supporting structure.
Recheck alignment after any change in shims and
document alignment readings for warranty information.
Completing Mechanical Installation
After controlling rotor end float and establishing
accurate alignment, it is recommended to drill and
ream the foundation plate and motor feet together for
dowel pins. (See Doweling).
Recheck parallel and angular alignment before bolting
the coupling together. Motor shaft should be level
within 0.03 inch after alignment.