Interface microstarter – switching, pro-
tecting and communicating in the mo-
tor terminal box
We have now reached another milestone
in distributed drive technology in the form
of the new AS-Interface microstarter.
You can now completely replace the mo-
tor terminal box by an AS-Interface mi-
crostarter up to 4 kW.
The motor can be mounted in any posi-
tion. Thanks to its compact design, the
AS-Interface Microstarter can be used
wherever space is especially tight. Elec-
tronic overload protection is especially
cool: The motor is continually monitored
using thermistor evaluation and when a
fault develops, it is automatically tripped.
However, the AS-Interface motor starter
can do a lot more. Signals, which are
available close to the motor (e.g. Bero
proximity switches) can be read-in using
the two digital inputs integrated in the
starter and can be transferred to the AS-
Interface master. This means that addi-
tional modules can be eliminated. Not
only this, the AS-Interface motor starter
can be integrated into Category 1 safety
concepts (in compliance with EN 954-1).
Integrated LEDs make local diagnostics
fast and precise. A fault signal is also im-
mediately sent to the AS-Interface mas-
ter – for a truly integrated drive solution.
K60R: The IP68 module for the
AS-Interface
The K60R module, with round cable
connection and degree of protection
IP68, is now available – and it supple-
ments the K45/K60 series of compact
modules with degree of protection
IP65/67. The new design can be operat-
ed in environments which have high
permanent levels of moisture. This re-
sults in many practical applications.
• Use in especially moist ambient con-
ditions, for example, in beverage filling
systems, on machine tools and in the
food and beverage industry.
• The K60R module, with degree of pro-
tection IP68, can now be cleaned under
high pressures and it is even possible to
use liquid cleaning agents capable of
film creep.
• The module is connected to the AS-
Interface bus and the auxiliary voltage
using a round cable which is connected
to the module using an M12 connector.
Microstarter
The direct-on-line and reversing starter
with communication capability and de-
gree of protection IP65 has a power of
up to 4 kW and can either be integrated
directly into the motor terminal box or
replace the terminal box completely. On
AS-Interface, the microstarter acts as a
standard slave with 4 inputs and out
AS-