Siemens SIMATIC PANEL PC 877 Operations Instructions Page 215

  • Download
  • Add to my manuals
  • Print
  • Page
    / 238
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 214
Detailed descriptions
16.5 Communications processor CP 1616 onboard
SIMATIC IPC677C
Operating Instructions, 05/2010, A5E02722710-01
215
16.5.2.1 Loading firmware
Start downloading procedure
1. In the Windows Start menu, select the menu command SIMATIC > STEP 7 > NCM S7 >
Firmware Loader.
2. Click "Next" and follow the instructions in the dialog fields that follow. A help function is
integrated in the software as support.
CAUTION
Ensure that the loader file you are using for the update is suitable for the version of
firmware on your module. If you have any doubts, contact your local Siemens
consultant.
CAUTION
Be aware that aborting the loading process may result in an inconsistent state in your
module.
You can find additional, detailed information about the individual loader variants in the
integrated help.
NOTICE
When loading the firmware or commissioning the module, be aware that the CP 1616
onboard takes five MAC addresses (always in direct sequence). The first two are shown in
the BIOS.
Page view 214
1 2 ... 210 211 212 213 214 215 216 217 218 219 220 ... 237 238

Comments to this Manuals

No comments