Siemens SIMATIC PANEL PC 877 Operations Instructions Page 133

  • Download
  • Add to my manuals
  • Print
  • Page
    / 238
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 132
SIMATIC IPC677C
Operating Instructions, 05/2010, A5E02722710-01
133
Alarm, error, and system messages
12
12.1 Boot error messages
BIOS first performs a Power On Self Test (POST) within the boot routine to verify proper
operation of certain functional units of the PC. The boot sequence is interrupted immediately
if fatal errors occur.
If the POST does not return an error, the BIOS initializes and tests further functional units. In
this startup phase, the graphics controller is initialized and any error messages are output to
the screen.
The error messages output by the system BIOS are listed below. For information on error
messages output by the operating system or programs, refer to the corresponding manuals.
On-screen error messages
On-screen error message Meaning / suggestions
Error - CMOS battery failed The battery on the CPU module is defective or dead.
Contact your technical support team.
Error - SMART failure detected
on HDD
Hard disk error: An error bound suggested by the manufacturer
has been exceeded. The operation of the hard disk is not secure.
The hard disk must be replaced. Contact your technical support
team.
Error - Keyboard error Check whether the keyboard is properly connected.
No bootable device -- Please
restart system
Possible causes:
No operating system present
Wrong drive addressed (disk in drive A/B)
Incorrect active boot partition
Wrong boot drive settings in SETUP
Hard disk is not connected / defective
Error - Realtime clock has lost
power
Clock chip error.
Contact your technical support team.
Error - Keyboard controller error Keyboard error.
Contact your technical support team.