configurable by the installer (default 10 minutes) to inform the user before the area
sets. The timer symbol will display next to the area at the configured warning time.
The keypad displays that the area will set in ‘X’ minutes or seconds. You will hear
an audible beep for each elapsed minute and every 10 seconds during the final
minute.
When the timer displays next to an area, 3 timer symbols display above the soft
keys:
Symbol
Function
To view the number of minutes left before the area sets:
Press the soft key below the Timer Info symbol.
Example:
TIME TO FULLSET
9 MIN 3 SEC
To delay setting by the configured time (default 30 minutes):
Press the soft key below the Delay Timer symbol.
Example:
TIME TO FULLSET
68 MIN 30 SEC.
You can press this soft key up to 3 times by default (configurable by
installer) to increment the configured time. In this case, the icon is no
longer displayed.
To cancel automatic setting for a standard area:
Press the soft key below the Cancel Timer symbol.
The Timer Info and Delay Timer icons are no longer displayed. You must
manually set this area.
6.6 Time Locked
Time locked applies to a vault type of area only. If time locked is applied to a vault
area, you can only unset the vault during times defined by the assigned calendar.
The padlock symbol is displayed next to the vault area to indicate when it cannot
be unset.