User programming via the keypad
Setting and unsetting the system
16
Siemens AB
A6V10209178
Security Products
26.09.2011
The system fails to set if there is an open or fault condition detected on an alarm
zone when the FULLSET or PARTSET A/B option is selected. The keypad
displays the zone number and description.
To set the system, locate the zone and close or fix the fault. Repeat the FULLSET
or PARTSET A/B operation.
6.1.3 PARTSET
The PARTSET option provides the following functionality:
Perimeter protection to a building while allowing free movement through the
exit and access areas
Exclusion of EXCLUDE A/B zones from protection
Instant activation of alarm on selection of mode; by default there are no exit
times associated with PARTSET A/B.
To select PARTSET A/B:
1. Scroll to PARTSET A or PARTSET B.
2. Press SELECT.
The LCD displays PARTSET A/B SET on the bottom line for approximately 10
seconds.
The system fails to set if there is an open or fault condition detected on an alarm
zone when the FULLSET or PARTSET A/B option is selected. The keypad
displays the zone number and description.
To set the system, locate the zone and close or fix the fault. Repeat the FULLSET
or PARTSET A/B operation.
6.1.4 FORCE TO SET
The system can be forced to set while an alarm zone is still open. This operation
inhibits the open zone and sets the system as normal.
To force to set the system:
1. Scroll to FULLSET or PARTSET A/B.
2. Press SELECT.
The keypad buzzer beeps and the first line of the display indicates the open
zone
3. Scroll to FORCED SET.
4. Press SELECT.
6.1.5 RESTORE
Alert conditions on the SPC system are indicated on the keypad by a flashing
yellow alert LED and by activation of the buzzer. The keypad indicates the location
and nature of the alert condition. The ability of a user to restore alerts depends on
the security grade setting of the system (in accordance with standards). An alert
condition can only be restored once the fault or zone that caused the alert has
been physically reset to its normal operating state; e.g. an open zone has been