The following is an example of setting system time and date as 10:20pm, July 4th, 2005.
SWITCH# clock 06 Mar 2006 10:20
Mon, 6 Mar 2006 10:20:00 GMT+0000
SWITCH#
6.1.3 Time Zone
The hiD 6615 S223/S323 provides three kinds of time zone, GMT, UCT and UTC. The
time zone of the switch is predefined as GMT (Greenwich Mean Time). Also you can set
the time zone where the network element belongs.
To set the time zone, use the following command (Refer to the below table).
Command Mode Description
time-zone TIMEZONE Global Sets the time zone.
show time-zone
Enable
Global
Shows the world time zone map.
Tab. 6.1 shows the world time zone.
Time Zone Country/City Time Zone Country/City Time Zone Country/City
GMT-12 Eniwetok GMT-3 Rio De Janeiro GMT+6 Rangoon
GMT-11 Samoa GMT-2 Maryland GMT+7 Singapore
GMT-10 Hawaii, Honolulu GMT-1 Azores GMT+8 Hong Kong
GMT-9 Alaska GMT+0 London, Lisbon GMT+9 Seoul, Tokyo
GMT-8 LA, Seattle GMT+1 Berlin, Rome GMT+10 Sydney,
GMT-7 Denver GMT+2 Cairo, Athens GMT+11 Okhotsk
GMT-6 Chicago, Dallas GMT+3 Moscow GMT+12 Wellington
GMT-5 New York, Miami GMT+4 Teheran
GMT-4 George Town GMT+5 New Delhi
Tab. 6.1 World Time Zone
6.1.4 Network Time Protocol
The Network Time Protocol (NTP) provides a mechanism to synchronize time on com-
puters across an internet. The specification for NTP is defined in RFC 1119.
To enable/disable the NTP function, use the following command.
Command Mode Description
ntp SERVER1 [[SERVER2]
SERVER3]]
Enables the NTP function with specified NTP server.
SERVER: server IP address
ntp start Operates the NTP function with specified NTP server.
no ntp