Siemens S223 User Manual Page 137

  • Download
  • Add to my manuals
  • Print
  • Page
    / 381
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 136
User Manual UMN:CLI
SURPASS hiD 6615 S223/S323 R1.5
A50010-Y3-C150-2-7619 137
The following is an example of configuring syslog message to send all logs higher than
notice to remote host 10.1.1.1 and configuring local1.info to transmit to console.
SWITCH(config)# syslog output notice remote 10.1.1.1
SWITCH(config)# syslog output priority local1 info console
SWITCH(config)# show syslog
System logger on running!
info local volatile
info local non-volatile
notice remote 10.1.1.1
local1.info console
SWITCH(config)#
7.5.2 Facility Code
You can set a facility code of the generated syslog message. This code make a syslog
message distinguished from others, so network administrator can handle various syslog
messages efficiently.
To set a facility code, use the following command.
Command Mode Description
syslog local-code <0-7> Sets a facility code.
no syslog local-code
Global
Deletes a specified facility code.
The following is an example of configuring priority of all syslog messages which is trans-
mitted to remote host 10.1.1.1, as the facility code 0.
SWITCH(config)# syslog output err remote 10.1.1.1
SWITCH(config)# syslog local-code 0
SWITCH(config)# show syslog
System logger on running!
info local volatile
info local non-volatile
err remote 10.1.1.1
local_code 0
SWITCH(config)#
7.5.3 Syslog Bind Address
You can specify IP address to attach to the syslog message for its identity. To specify IP
address for syslog identity, use the following command.
Command Mode Description
syslog bind-address A.B.C.D Specifies IP address for a syslog message identity.
no syslog bind-address
Global
Deletes a specified binding IP address.