RUGGEDCOM RSG2200
Installation Guide
2 Ports, Controls and Indicator LEDs
Exceeds IEC 61850-3 (electric utility substations)
Exceeds IEC 61800-3 (variable speed drive systems)
Exceeds NEMA TS-2 (traffic control equipment)
Exceeds IEC 61000-6-2 (generic industrial environment)
-40 to 85 °C (-40 to 185 °F) operating temperature (no fans)
Conformal coated printed circuit boards (optional)
18 AWG galvanized steel enclosure
Universal Power Supply Options
Fully integrated, dual-redundant (optional) power supplies
Universal high-voltage range: 88-300 VDC or 85-264 VAC
Popular low voltage ranges: 24 VDC (10-36 VDC), 48 VDC (36-72 VDC)
Screw or pluggable terminal blocks for reliable, maintenance-free connections
CSA/UL 60950-1 safety approved to 85 °C (185 °F)
Section 1.2
Ports, Controls and Indicator LEDs
The RSG2200 features various ports, controls and indicator LEDs on the front panel for configuring and
troubleshooting the device.
5
1
3 6
4
2
Figure 1: Front Panel
1. Port Status Indicator LEDs 2. Display Mode Indicator LEDs 3. Mode Button 4. Alarm Indicator LED 5. Power Module Indicator
LEDs 6. RS232 Serial Console Port (RJ45)
Port Status Indicator LEDs These LEDs indicate the state of each port.
When Status mode is selected, these LEDs indicate when ports are active.
Green (Solid) = Link detected
Green (Blinking) = Link activity
Off = No link detected
When Duplex mode is selected, these LEDs indicate when ports are operating in full or half
duplex mode.
Green (Solid) = Full duplex mode