Type Tests
6.1.2 IEEE 1613 Type Tests
IEEE Test
IEEE
1613
Clause
Description Test Levels
Enclosure Contact +/- 2kV , +/- 4kV , +/- 8kV
C37.90.3 9 ESD
Enclosure Air +/- 4kV , +/- 8kV , +/- 15kV
C37.90.2 8 Radiated RFI Enclosure ports 35 V/m
Signal ports +/- 4kV @ 2.5kHz
D.C. Power ports +/- 4kV
A.C. Power ports +/- 4kV
C37.90.1 7 Fast Transient
Earth ground ports +/- 4kV
Signal ports 2.5kV common mode @ 1MHz
D.C. Power ports 2.5kV common, 1kV differential mode @ 1MHz
C37.90.1 7 Oscillatory
A.C. Power ports 2.5kV common, 1kV differential mode @ 1MHz
Signal ports 5 kV (Failsafe Relay)
D.C. Power ports 5 kV
C37.90 6 H.V. Impulse
A.C. Power ports 5 kV
Signal ports 2kV AC
D.C. Power ports 1.5kV DC
C37.90 6 Dielectric Strength
A.C. Power ports 2kV AC
Table 8 - IEEE 1613 Type Tests
Notes:
If the unit contains copper ports the IEEE 1613 conformance is Class 1 (During
disturbance errors may occur but recovery is automatic).
If the unit contains all fiber ports the IEEE 1613 conformance is Class 2 (During
disturbance no errors will occur).
6.1.3 IEC Environmental Type Tests
Test Description Test Levels
IEC 60068-2-1 Cold Temperature Test Ad -40 deg. C, 16 Hours
IEC 60068-2-2 Dry Heat Test Bd +85 deg. C, 16 Hours
IEC 60068-2-30
Humidity (Damp
Heat, Cyclic)
Test Db 95% (non-condensing), 55°C, 6 cycles
IEC 60255-21-1 Vibration 2g @ (10-150) Hz
IEC 60255-21-2 Shock 30g @ 11 ms
Table 9 - Environmental Type Tests
Note:
1. Ruggedcom specified security levels
2. Meets Class 2 requirements for an all fiber configuration. Class 1 for copper ports.