Installation
4.6 Console Port Wiring
A RS232 console port for configuration and management of the device is located on the LED
display module shown in Figure 22. This port is intended to be a temporary connection during
initial configuration or troubleshooting and allows for direct access to the serial-based management
console. The connection is made using the DB9-Female to RJ45 console cable included in the
device packaging shown in Figure 23. Console connection settings are: 57600 baud, no parity
bits, 8 data bits, and 1 stop bit.
Figure 22: Console port location on display board Figure 23: RSG2200 Console cable
For user reference, the console cable pin-out is show in Table 5.
RuggedCom RS232 over RJ45 pin-out specification
Si
nal Name
PC is DTE
DB9-
Female
RJ45 Male
DCD
Carrier detect 1
2
RxD
Receive data
to DTE
2
5
TxD
Transmit data
from DTE
3
6
DTR
Data terminal read
4
3
Si
nal GND 5
4
DSR
Data set read
6
1*
RTS
Read
to send 7
8
CTS
Clear to send 8
7
RI
Rin
Indicator 9
1*
Table 4: RS232 over RJ45 console cable pin-out
After initial configuration, the device can be configured via a number of new mechanisms such as
Telnet, SSH and the built-in web server. Consult the ROS
®
User Guide for further details.
NOTE: This port is not intended to be a permanent connection and the cable shall be less than 2m
(6.5 ft) in length.