Configuration Using the Wizards of Web Based Management
Operating Instructions SCALANCE W78x
69
dress Settings (Client Mode only)
Assigning
ernet port of
the SCALANCE W78x client before it can be reached. This MAC address is used
client for wireless communication with the access point.
nt,
Automatically, the client adopts the source MAC address of the first frame
that it receives over the Ethernet interface.
Manual entry by the user.
s.
AC addresses need to be served downstream from the client,
the following setting is available for SCALANCE W746-1PRO and SCALANCE
W747-1RR:
Layer 2 Tunneling
This setting meets the requirements of industrial applications in which MAC
address-based communication with several devices downstream from the client
is required. Clients with this setting cannot connect to standard Wi-Fi devices
and SCALANCE W access points with firmware V3.0 or older.
Note
The layer 2 tunneling setting is available only with the following model variants:
SCALANCE W78x in client mode
SCALANCE W746-1PRO
SCALANCE W747-1RR
C79000-G8976-C184-07
5.4.6 Adopt MAC Ad
the MAC Address
A MAC address must be specified for the device connected to the Eth
by the
If there is precisely one MAC address to be served downstream from the clie
there are two ways of doing this:
These settings have no effect on communication with standard Wi-Fi device
If up to eight M
The SCALANCE W746-1PRO and SCALANCE W747-1RR devices can also
provide access to a wireless network for several Ethernet devices (IP mapping).
For an access point with MAC filtering, only one MAC address is visible to the
SCALANCE W78x client, there can be no filtering according to the MAC addresses
of the Ethernet devices.