2.1 Basic information on Ethernet switching
SCALANCE X-300
10 Operating Instructions, 01, A5E01113043
Configuration example
Sample electrical configurations with SCALANCE X310, SCALANCE X-200, SIMATIC S7-
300/400, SIMATIC ET 200, and operator panels as end devices.
S7-300S7-400
ET 200S
SCALANCE
X208
SCALANCE X310
SCALANCE
X208
SCALANCE
X208
S7-400 S7-300 S7-300
ET 200S ET 200S ET 200S
ET 200S
ET 200S
SCALANCE
X310
Figure 2-2 Star structure (electrical)
2.1.3 Ring with redundancy manager
Ring with redundancy manager
To increase availability, linear (bus) topologies of up to 50 switches can be closed to form a
ring:
Optical: SCALANCE X-400, SCALANCE X-300
Electrical: SCALANCE X-400, SCALANCE X-300, SCALANCE X-200 or ESM
Functional description
The two ends of the bus are closed to form a ring by an IE Switch X-300 operating as a
redundancy manager.
The redundancy manager function is enabled by the SELECT/SET button or implemented by
a setting in the software.
For more detailed information, refer to the configuration manual "Industrial Ethernet Switches
SCALANCE X-300 SCALANCE X-400."
In contrast to the ring ports of the other IE Switches X-300, the ring ports of the redundancy
manager are disconnected when the network is operating problem-free. The IE Switch X-300
operating in the redundancy manager mode monitors the connected bus over its ring ports
and switches the ring ports through if there is an interruption on the connected bus; in other
words, it restores a functioning bus over this substitute path. Reconfiguration is achieved