3VU13 Circuit - breakers with 1NO+1NC auxiliary contacts for
line-side protection of transformers with high inrush current
Rated Overload Shortcircuit Type Std.
Current release release pkg.
In range setting (nos.)
AAA
0.6 0.4-0.6 12 3VU1340-1TE00
1 0.6-1 15 3VU1340-1TF00
1.6 1-1.6 29 3VU1340-1TG00
2.4 1.6-2.4 48 3VU1340-1TH00
4 2.4-4 72 3VU1340-1TJ00 1
6 4-6 120 3VU1340-1TK00
10 6-10 190 3VU1340-1TL00
16 10-16 300 3VU1340-1TM00
20 14-20 300 3VU1340-1TN00
Fuse monitoring motor protection circuit - breakers with
1NO+1NC auxiliary contacts
Rated Overload Shortcircuit Type Std.
Current release release pkg.
In range setting (nos.)
AAA
0.2 0.2 1.2 3VU1340-1MS00 1
3VU16 Circuit - breakers with 1NO+1NC auxiliary contacts for
motor and plant protection
Rated Overload Shortcircuit Type
$
Recommended Std.
Current release release 415V Motor pkg.
In range setting Rating in (nos.)
A A A Kw/HP (DOL)
10 6-10 120 3VU1640-1ML00 4/5.4
16 10-16 190 3VU1640-1MM00 7.5/10
25 16-25 300 3VU1640-1MN00 11/15 1
32 22-32 380 3VU1640-1MP00 15/20
40 28-40 480 3VU1640-1MQ00 18.5/25
52 36-52 600 3VU1640-1MR00 22/30
3VU16 Circuit - breakers for plant protection
Rated Overload Shortcircuit Type
$
Std.
Current release release pkg.
In range setting (nos.)
AAA
63 45-63 600 3VU1640-1LS00 1
$
The 3VU13 and 3VU16 circuit breakers are also available without auxiliary
contacts. To order the same, the 8th place of the type number is to be replaced
with the digit 0.
Current Limiting is achieved in 3VU as follows
In case of a short circuit, the contacts are opened electro-
dynamically by the short circuit current. The instantaneous
overcurrent release, through the switching mechanism, trips all
the three poles of the breaker. A large arc voltage is quickly
built up in the arc chamber limiting the short circuit current.
Thus ensures faster fault clearing.
Ambient temperature compensation upto 55
o
C hence no
deration required upto 55
o
C.
Safety
Trip Free Mechanism
The breakers have a trip-free mechanism. Even by holding the
toggle, tripping operation can not be stopped or blocked once
it is started. Thus ensure positive opening in the event of fault.
Positive ON/OFF indication through toggle switch
Compact and space saving
User friendliness and safety
SIGUT® connection technique ensures ease of wiring (can
obviate use of lug)
Fingers touch proof terminals ensures operator safety
Separate trip indication on short circuit and overload fault
using alarm contact
Flexibility
Can be used as a main and EMERGENCY STOP switch.
Identical accessories reduce stock levels
Selection and ordering data
3VU13 Circuit - breakers with 1NO+1NC auxiliary contacts for
motor and plant protection
Rated Overload Shortcircuit Type
$
Recommended Std.
Current release release 415V Motor pkg.
In range setting Rating in (nos.)
A A A Kw/HP (DOL)
0.16 0.1 - 0.16 1.9 3VU1340-1MB00
0.24 0.16 - 0.24 2.9 3VU1340-IMC00
0.4 0.24-0.4 4.8 3VU1340-1MD00
0.6 0.4-0.6 7.2 3VU1340-1ME00
1 0.6-1 12 3VU1340-1MF00 0.25/0.33
1.6 1-1.6 19 3VU1340-1MG00 0.37/0.5
2.4 1.6-2.4 29 3VU1340-1MH00 0.75/1
3.2 2-3.2 38 3VU1340-1NH00 1.1/1.5
4 2.4-4 48 3VU1340-1MJ00 1.5/2 1
5 3.2-5 60 3VU1340-1NJ00 2.2/3
6 4-6 72 3VU1340-1MK00 3/4
8 5-8 96 3VU1340-1NK00 3.7/5
10 6-10 120 3VU1340-1ML00 4/5.4
13 8-13 156 3VU1340-1NL00 5.5/7.5
16 10-16 190 3VU1340-1MM00 7.5/10
20 14-20 240 3VU1340-1MN00 9.3/12.5
25 18-25 300 3VU1340-1MP00 11/15