System interfaces
Trunks
•S
0
(basic rate interface)
•E1 (S
2M
) (primary rate interface
30 channels)
• T1 (primary rate interface 24 channels)
•Analog
• Native SIP (SIP service provider)
Networking interfaces
•Basic Rate S
0
/ Primary Rate E1 (S
2M
) / T1
The following protocols are supported:
CorNet NQ, QSIG, DSS1, CAS
• Analog e.g. MFC-R2, E&M, ...
• IP trunking (H.323 Annex M1)
• SIP trunking to HiPath platforms with
SIP-Q protocol
• Native SIP trunking for IP interoperability
with 3rd-party manufacturers
User interfaces
•U
P0/E
Twin-wire interface for connecting
OpenStage T telephones
• HiPath Feature Access (HFA) for
OpenStage HFA endpoints
• Native SIP for IP Endpoints:
e.g. OpenStage SIP
•S
0
bus
S
0
port for ISDN terminal devices
• a/b port (CLIP, name display, and MWI
possible) for analog terminal devices
CSTA standards
• ECMA-269: Services for Computer Sup-
ported Telecommunications Applicati-
ons (CSTA) Phase III
• ECMA-323: XML Protocol for
CSTA Phase III
• ECMA-285: ASN1 Protocol for
CSTA Phase III
• ECMA TR/82: Scenarios for
CSTA Phase III
Integral service platform
• Transport and network protocol TCP/IP
• Asynchronous protocol PPP
• Web protocol https
• Remote access via Ethernet or via
modem
• SNMP Proxy Agent
•SFTP for Backup&Restore
Environmental operating conditions
A "buffered" 48-volt direct current power supply can also be used.
Dimensions and weight
Air temperature in operation (air cooling) +5 °C to +40 °C
Relative air humidity max. 85%
Width x Height x Depth (mm) Weight
HiPath 4000
Communication Server
440 x 170 x 300 (5 U) max. 13 kg
HiPath AP 3300 773 x 645 x 515 max. 30 kg
HiPath AP 3700 440 x 445 x 433 (11 U) max. 25 kg
HiPath AP 3300 IP 773 x 645 x 515 max. 30 kg
HiPath AP 3700 IP 440 x 445 x 433 (11 U) max. 22 kg
Power supply voltage
Compliance
Single Phase 100 V - 240 V
Three Phase 190 V/400 V
Safety EN60950
EMC Emission EN55022 Class A
EMC Immunity EN55024 and
EN1000-6-2
Technical Data
Variant Number
of directly connected access points
Number
of IP-distributed access points
Number
of digital/IP subscribers
HiPath 4000 up to 15 up to 83 up to 12,000
Comments to this Manuals