Siemens Industrial Ethernet Switches SCALANCE X-200 User Manual Page 210

  • Download
  • Add to my manuals
  • Print
  • Page
    / 296
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 209
Configuration / diagnostics using remote mechanisms
6.3 Configuration using Web Based Management (WBM) and Command Line Interface (CLI)
SCALANCE X-200
210 Operating Instructions, 12/2011, A5E00349864-19
SIMATIC time
If you use the SIMATIC time transmitter, you do not need to make any further settings.
Manual
Here, an input field opens for you to enter the current time. The time is quartz controlled
and thus always exact. When you switch off or reset the device, this information is lost
and must be entered again.
Time zone offset
You can enter a time zone correction for the SNTP protocols here.
Time server
Here, you can enter the Internet address of the server with which the system time will be
synchronized. The number of the UDP port being used can also be entered. As default, the
SNTP protocol uses UDP port 123.
Init poll interval
Here, you can enter the interval at which the IE Switch X200 repeats the initial poll for the
system time if this was not successful the first time.
Poll interval
Once the system time has been adopted the first time from the time server, it is updated
cyclically with renewed polls to the time server. Here, you specify how often the updates take
place.
Syntax of the Command Line Interface
Table 6- 22 Agent Time Client Configuration - CLI\AGENT\TIME>
Command Description Comment
info Displays information on the time
settings of the IE switch.
timec [E ¦ D] Enables / disables the time
settings of the IE switch.
Administrator only.
server [IP address] [:port] Sets the IP address and the port
of the server.
Administrator only.
tzone [-12..+12] Sets the time difference in hours
between the server and system
time.
Administrator only.
tinitpoll [1000-100000ms] Specifies the polling interval …? Administrator only.
tpoll [10-100000s] Specifies the polling interval in
the range from 10 - 100000 s.
Administrator only.
ttype [P ¦ L ¦ S ¦ M] Specifies how the time is set:
- P SNTP poll
- L SNTP listen
- S Siemens
- M manual.
Administrator only.
settime [time] Sets the time manually
(DD MMM HH:MM:SS YYYY).
Administrator only.