FENWALL BURNER CONTROL C/W
WIRING LOOM
12 VDC•
Integral Ignition transformer•
Inter purge time 25 seconds•
Trial for ignition time ( TFI ) 10 •
seconds
# FW-35-53056-035
System Control Engineering NZ Ltd For Gas Combustion & Control Equipment
Tel : 09-636-1401 • Fax: 09-636-1525 • [email protected] • www.systemcontrol.co.nz
Programmed oil & gas Burner Controls
1
A Honeywell Company
300e/04 /98
For 1- or 2-stage oil power burners up to
30kg/h capacity and intermittent operations.
Flame detection:
- Photoresistor FZ 771 S
- Infrared-flicker detector IRD 1010
- UV solid state sensor UVD 970
Oil Burner Safety Control
TF 801 / 801.2
TF 802 / 802.2
TECHNICAL DATA
Operating voltage 220/240 V (-15..+10%)
50 Hz (40-60Hz)
Fuse rating 10 A fast, 6 A slow
Power consumption ca. 5 VA
Max. load per output
- terminal 3 1.5 A, cos ϕ 0.2
- terminal 4 4 A, cos ϕ 0.4
- terminal 5 0.5 A, cos ϕ 0.4
- terminal 6 0.5 A, cos ϕ 0.4
- terminal 7 0.1 A, cos ϕ 0.4
total load 5A, cos ϕ 0.4
Pre-purge time ca. 12 sec.
Pre-ignition time ca. 12 sec.
Post-ignition time TF 801/TF801.2 ca. 20 sec.
TF 802/TF802.2 ca. 2-4 sec
Delay time to oil valve 2 40 sec. (TF 802)
Lockout safety time 10 sec.
Reset time from lockout ca. 90 sec
Flame detector:
FZ 771 S red side-on viewing
FZ 771 S white side-on and end-on
viewing
Light sensitivity FZ 711S > 10 Lux
IRD 1010 side-on or end-on
viewing
UVD 970 end-on viewing
Weight incl. wiring base 0.25 kg
Mounting position any
Protection class IP44
Recommended ambient operating
temperature for control and
flame detector 0°C...+60°C
approved and certified according
to European standards
TF 801.2/TF802.2 EN 230
TF 801/TF802 DIN 4787
APPLICATION RANGE
The TF 801 or TF 802 oil burner safety control boxes are
suitable to control and monitor oil power burner up to 30 kg/
h capacity (approved and certified according to DIN 4787).
The control boxes TF 801.2 and TF 802.2 are approved and
certified according to EN230.
TYPES AVAILABLE
TF 801 1-stage operation
post-ignition time ca. 20 sec.
TF 801.2 1-stage operation
post-ignition time ca. 20 sec.
low voltage protection according to EN230
TF 802 2-stage operation
post-ignition time 2-4 sec.
TF 802.2 2-stage operation
post-ignition time 2-4 sec.
low voltage protection according to EN230
CONSTRUCTIONAL FEATURES
The control box circuitry is protected by a flame resistant,
transparent plastic housing. It incorporates the thermo-
mechanical, temperature compensated timer, flame check
and reset circuits.
Manual reset from lockout is provided by a push button with
an integrated lockout signal lamp. A central fixing screw
locks the control box to the wiring base. The wiring base and
control box have a positive plug-in arrangement, making it
impossible to achieve an incorrect connection between the
two parts. A variety of cable entry points provides utmost
flexibility of electrical wiring.
The TF 802.2 is fully compatible with the TF 701,
701-1 and TF 802. The flame detector IRD 910
must be replaced by its compatible type IRD
1010.
An optional extension button (item no. 70601)
compensates for height differences.
Satronic TF801- OIL BURNER
CONTROLLER
Oil burner control•
Plug in base (SA7531001)•
Single stage operation•
FZ 771 / IRD 1010 / UVD 970 Flame •
detector
Pre - purge 12 seconds•
Post ignition time 2 - 5 seconds•
Manual reset from lockout•
240 volt AC•
#SA02001
1
A Honeywell Company
300e/04 /98
For 1- or 2-stage oil power burners up to
30kg/h capacity and intermittent operations.
Flame detection:
- Photoresistor FZ 771 S
- Infrared-flicker detector IRD 1010
- UV solid state sensor UVD 970
Oil Burner Safety Control
TF 801 / 801.2
TF 802 / 802.2
TECHNICAL DATA
Operating voltage 220/240 V (-15..+10%)
50 Hz (40-60Hz)
Fuse rating 10 A fast, 6 A slow
Power consumption ca. 5 VA
Max. load per output
- terminal 3 1.5 A, cos ϕ 0.2
- terminal 4 4 A, cos ϕ 0.4
- terminal 5 0.5 A, cos ϕ 0.4
- terminal 6 0.5 A, cos ϕ 0.4
- terminal 7 0.1 A, cos ϕ 0.4
total load 5A, cos ϕ 0.4
Pre-purge time ca. 12 sec.
Pre-ignition time ca. 12 sec.
Post-ignition time TF 801/TF801.2 ca. 20 sec.
TF 802/TF802.2 ca. 2-4 sec
Delay time to oil valve 2 40 sec. (TF 802)
Lockout safety time 10 sec.
Reset time from lockout ca. 90 sec
Flame detector:
FZ 771 S red side-on viewing
FZ 771 S white side-on and end-on
viewing
Light sensitivity FZ 711S > 10 Lux
IRD 1010 side-on or end-on
viewing
UVD 970 end-on viewing
Weight incl. wiring base 0.25 kg
Mounting position any
Protection class IP44
Recommended ambient operating
temperature for control and
flame detector 0°C...+60°C
approved and certified according
to European standards
TF 801.2/TF802.2 EN 230
TF 801/TF802 DIN 4787
APPLICATION RANGE
The TF 801 or TF 802 oil burner safety control boxes are
suitable to control and monitor oil power burner up to 30 kg/
h capacity (approved and certified according to DIN 4787).
The control boxes TF 801.2 and TF 802.2 are approved and
certified according to EN230.
TYPES AVAILABLE
TF 801 1-stage operation
post-ignition time ca. 20 sec.
TF 801.2 1-stage operation
post-ignition time ca. 20 sec.
low voltage protection according to EN230
TF 802 2-stage operation
post-ignition time 2-4 sec.
TF 802.2 2-stage operation
post-ignition time 2-4 sec.
low voltage protection according to EN230
CONSTRUCTIONAL FEATURES
The control box circuitry is protected by a flame resistant,
transparent plastic housing. It incorporates the thermo-
mechanical, temperature compensated timer, flame check
and reset circuits.
Manual reset from lockout is provided by a push button with
an integrated lockout signal lamp. A central fixing screw
locks the control box to the wiring base. The wiring base and
control box have a positive plug-in arrangement, making it
impossible to achieve an incorrect connection between the
two parts. A variety of cable entry points provides utmost
flexibility of electrical wiring.
The TF 802.2 is fully compatible with the TF 701,
701-1 and TF 802. The flame detector IRD 910
must be replaced by its compatible type IRD
1010.
An optional extension button (item no. 70601)
compensates for height differences.
Satronic TF802- OIL BURNER
CONTROLLER
Oil burner control•
Plug in base (SA7531001)•
2 stage operation•
FZ 771 / IRD 1010 / UVD 970 Flame •
detector
Pre - purge 12 seconds•
Post ignition time 2 - 5 seconds•
Manual reset from lockout•
240 volt AC•
#SA02404