Siemens MC55 User Manual Page 23

  • Download
  • Add to my manuals
  • Print
  • Page
    / 31
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 22
Page 23 of 31
GSM Status – R/W at GSM BASE + 402h (00h after reset)
GSM Status Write GSM BASE + 402h
Bit 0 RESERVED
Bit 1 /EN_INT UART interrupt enabled; 1 - disabled
Bit 2 RESERVED
Bit 3 RESERVED
Bit 4 RESERVED
Bit 5 RESERVED
Bit 6 RESERVED
Bit 7 RESERVED
GSM Status
Read GSM BASE + 402h
Bit 0 /EN_RST 1 – Reset GSM in reset, 0 – GSM active
Bit 1 /EN_INT GSM interrupt enabled; 1 – disabled
Bit 2 TEMP_LOW 1 - Board temperature below -20C
Bit 3 TEMP_HIGH 1 - Board temperature over +70C
Bit 4 RESERVED
Bit 5 RESERVED
Bit 6 RESERVED
Bit 7 RESERVED
GSM Control – R/W at GSM BASE + 403h (00h after reset)
GSM Control Write GSM BASE + 403h
Bit 0 Ignition signal 1 – > 0 – results in IGN signal
Bit 1 Powerdown MC55 1 – Power down; 0 – Power on
Bit 2 RESERVED
Bit 3 RESERVED
Bit 4 RESERVED
Bit 5 RESERVED
Bit 6 RESERVED
Bit 7 RESERVED
GSM Control Read GSM BASE + 403h
Bit 0 Ignition signal State of Ignition Bit
Bit 1 Powerdown MC55 1 – Power down; 0 – Power on
Bit 2 RESERVED
Bit 3 RESERVED
Bit 4 RESERVED
Bit 5 RESERVED
Bit 6 RESERVED
Bit 7 RESERVED
Page view 22
1 2 ... 18 19 20 21 22 23 24 25 26 27 28 29 30 31

Comments to this Manuals

No comments