The switch shown in Figure 16 may be used to decelerate a
motor to a minimum speed. Closing the switch between S1 and S2
decelerates the motor from set speed to a minimum speed
determined by the MIN SPD trimpot setting. If the MIN SPD trimpot
is set full CCW, the motor decelerates to zero speed when the
switch between S1 and S2 is closed. The DECEL trimpot setting
determines the rate at which the drive decelerates. By opening the
switch, the motor accelerates to set speed at a rate determined by
the ACCEL trimpot setting.
Figure 17. Run/Decelerate to Minimum Speed Switch
Operation