EN2409EN00EN_0001
© 2007 Siemens AG
Siemens
1
Common Gateway
1 Common Gateway (CG). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
1.1 Gateways . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
1.2 Hardware and Loadware NCUI. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
1.3 General Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
1.4 Hardware and Loadware HG3500 V4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
1.5 General Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
1.6 Restrictions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
1.7 Impact On Existing Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
1.8 Number of B Channels Dependent On Enabled Features . . . . . . . . . . . . . . . . . . . . . . . . 9
1.8.1 STMI2 (Q2316-X10) / NCUI2+ (Q2305-X40) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
1.8.2 STMI4 (Q2324-X510) / NCUI4 (Q2324-X10) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
2 Architecture and System Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
2.1 Prerequisites . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
2.2 Power Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
2.3 Network Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
2.4 Basic Configuration Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
2.5 Bandwidth Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
2.5.1 Encoding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
2.5.2 Sampling Time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
2.5.3 IP Overhead . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
2.5.4 Required Bandwidth per Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
2.5.5 Voice Activity Detection (VAD) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
2.5.6 DMC Considerations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
2.6 Traffic Considerations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
3 Capacities and Limitations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Page view 0
1 2 ... 54

Summary of Contents

Page 1 - Common Gateway

EN2409EN00EN_0001© 2007 Siemens AGSiemens1Common Gateway1 Common Gateway (CG). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 2 - EN2409EN00EN_0001

OverviewEN4442EN00EN_0002© 2007 Siemens AGSiemens10

Page 3

Architecture and System RequirementsEN4442EN00EN_0002© 2007 Siemens AGSiemens112 Architecture and System Requirements2.1 PrerequisitesPrior to install

Page 4

Architecture and System RequirementsEN4442EN00EN_0002© 2007 Siemens AGSiemens12Frequently, only explicitly familiar TCP/IP or UDP/IP port numbers are

Page 5 - 1 Common Gateway (CG)

Architecture and System RequirementsEN4442EN00EN_0002© 2007 Siemens AGSiemens13On the HG 3500 these parameters are set by using standard switch admini

Page 6 - 1.3 General Information

Architecture and System RequirementsEN4442EN00EN_0002© 2007 Siemens AGSiemens14For telephony applications, voice is sampled every 125 μs at 8bits. It

Page 7 - 1.5 General Information

Architecture and System RequirementsEN4442EN00EN_0002© 2007 Siemens AGSiemens15Note that the bandwidth calculation is based on 70 bytes of overhead: R

Page 8 - 1.6 Restrictions

Architecture and System RequirementsEN4442EN00EN_0002© 2007 Siemens AGSiemens162.5.6 DMC ConsiderationsWhenever a DMC connection is established, a “Ma

Page 9

Architecture and System RequirementsEN4442EN00EN_0002© 2007 Siemens AGSiemens172.6 Traffic ConsiderationsFrom a trafficking point of view, HG 3500 IP

Page 10 - Overview

Architecture and System RequirementsEN4442EN00EN_0002© 2007 Siemens AGSiemens18

Page 11 - 2.3 Network Requirements

Capacities and LimitationsEN4442EN00EN_0001© 2007 Siemens AGSiemens193 Capacities and Limitations● The HiPath HG 3500 line gateway has the capacity to

Page 12 - EN4442EN00EN_0002

EN2409EN00EN_0001© 2007 Siemens AGSiemens24 Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 13 - 2.5.2 Sampling Time

Capacities and LimitationsEN4442EN00EN_0001© 2007 Siemens AGSiemens20

Page 14 - 2.5.3 IP Overhead

FeaturesEN4442EN00EN_0001© 2007 Siemens AGSiemens214 FeaturesThe HiPath HG 3500 line gateway provides a unique set of features described in the follow

Page 15

FeaturesEN4442EN00EN_0001© 2007 Siemens AGSiemens224.4 MobilityHG 3500 gateways support mobility.HFA Mobility provides all functions and features that

Page 16 - 2.5.6 DMC Considerations

FeaturesEN4442EN00EN_0001© 2007 Siemens AGSiemens23● Starting the optiClient 130 on a PC from any location automatically logs off the office IP phone

Page 17 - 2.6 Traffic Considerations

FeaturesEN4442EN00EN_0001© 2007 Siemens AGSiemens24noise and “silence“ are transmitted. Voice activity detection makes use of this knowledge, interrup

Page 18

FeaturesEN4442EN00EN_0001© 2007 Siemens AGSiemens25● Lost packets on VoIP payload connections between IP clients.● Jitter for VoIP payload connections

Page 19 - 3 Capacities and Limitations

FeaturesEN4442EN00EN_0001© 2007 Siemens AGSiemens26HG 3500 Front ViewThe HG 3500 provides three interfaces that are accessible to the user:1. One RS-2

Page 20 - Capacities and Limitations

FeaturesEN4442EN00EN_0001© 2007 Siemens AGSiemens274.14.2 Access to SNMPThe acces to SNMP is restricted via read and write Community strings. These Co

Page 21 - 4 Features

FeaturesEN4442EN00EN_0001© 2007 Siemens AGSiemens281. Adding one or multiple standby gateways to the system protects against individual gateway failur

Page 22 - 4.5 Secondary Clients

FeaturesEN4442EN00EN_0001© 2007 Siemens AGSiemens29For more details please refor to Chapter 14, “Standby Board HG 3500”.4.15.2.3 Secondary GatewaysIn

Page 23 - 4.8 Voice Compression

EN2409EN00EN_0001© 2007 Siemens AGSiemens37.2 General Operations. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 24 - 4.12 QOS Support

FeaturesEN4442EN00EN_0001© 2007 Siemens AGSiemens30>ImportantSecondary gateways and IP clients have to reside within the same system!Secondary gate

Page 25 - 4.13 Physical Interfaces

Configuration Common GatewayEN4442EN00EN_0002© 2007 Siemens AGSiemens315 General Information on How to Configure a HG 3500 V4 Common Gateway5.1 Genera

Page 26 - 4.14 Security

Configuration Common GatewayEN4442EN00EN_0002© 2007 Siemens AGSiemens32● Functions are consolidated on a single board using the AMO BCSU.● The DB line

Page 27 - EN4442EN00EN_0001

Configuration Common GatewayEN4442EN00EN_0002© 2007 Siemens AGSiemens33● For HFA and SIP, the number of circuits (LINECNT) and the number of B channel

Page 28

Configuration Common GatewayEN4442EN00EN_0002© 2007 Siemens AGSiemens34You can check the status with DISPLAY-BFDAT:FCTBLK=<number>;If the config

Page 29

Multiple-Feature Configuration EN4442EN00EN_0002© 2007 Siemens AGSiemens356 Multiple Feature Support Configuration at the Common Gateway (Example)6.1

Page 30

Multiple-Feature ConfigurationEN4442EN00EN_0002© 2007 Siemens AGSiemens36Functional block 3Functional block 3: IP trunking, HFA subscriber function (H

Page 31 - 3500 V4 Common Gateway

Multiple-Feature Configuration EN4442EN00EN_0002© 2007 Siemens AGSiemens37AMO CGWB not necessary because the IP address is already configured with the

Page 32 - 5.2 Rules

Multiple-Feature ConfigurationEN4442EN00EN_0002© 2007 Siemens AGSiemens38CHANGE-BFDAT:CONFIG=CONT,FCTBLK=4,FUNCTION=HG3550,LINECNT=1,UNITS=1;>>&

Page 33

Command Line Interface CLI at HG 3500EN4442EN00EN_0001© 2007 Siemens AGSiemens397 Command Line Interface CLI at HG 35007.1 General InformationThe comm

Page 34 - 5.3 Restrictions

EN2409EN00EN_0001© 2007 Siemens AGSiemens4

Page 35 - Common Gateway (Example)

Command Line Interface CLI at HG 3500EN4442EN00EN_0001© 2007 Siemens AGSiemens407.3 Access control● The configuration write access has to be acquired

Page 36 - 6.3 Configuration of a IPDA

Command Line Interface CLI at HG 3500EN4442EN00EN_0001© 2007 Siemens AGSiemens41/evtlog/evtlog.txt/evtlog/evtlog.bak7.6 MaintenanceThe maintenance com

Page 37 - 6.5 Configuring SIP Trunking

Command Line Interface CLI at HG 3500EN4442EN00EN_0001© 2007 Siemens AGSiemens42show if counters● To list all existing interfaces:show interfaces● To

Page 38

Command Line Interface CLI at HG 3500EN4442EN00EN_0001© 2007 Siemens AGSiemens43show fingerprintBefore accepting a certificate warning in the browser,

Page 39 - 7.2 General Operations

Command Line Interface CLI at HG 3500EN4442EN00EN_0001© 2007 Siemens AGSiemens44<LW-version><LW-version> holds the currently loaded loadwa

Page 40 - 7.5 Image/File Handling

Technical Data HG 3570/3575EN4442EN00EN_0001© 2007 Siemens AGSiemens458 Technical Data for HG 3500/3575● LAN Interface● 10/100-Base-T Fast Ethernet in

Page 41 - 7.6 Maintenance

Technical Data HG 3570/3575EN4442EN00EN_0001© 2007 Siemens AGSiemens46● Jitter Buffer - fixed size, adjustable between 0 and 210 ms● Network Managemen

Page 42 - 7.7 SSL for WBM

Technical Data HG 3570/3575EN4442EN00EN_0001© 2007 Siemens AGSiemens47The delay (mouth to ear) is calculated as:Sample Size + Network Delay + Jitter B

Page 43

Technical Data HG 3570/3575EN4442EN00EN_0001© 2007 Siemens AGSiemens48

Page 44 - <LW-version>

EN4442EN00EN_0002© 2007 Siemens AGSiemens499 Questions and Exercises to the Common GatewayQuestions9.1 Which boards can be used in a HiPath 4000 V4 as

Page 45

OverviewEN4442EN00EN_0002© 2007 Siemens AGSiemens51 Common Gateway (CG)The Common Gateway combines the different IP Gateway functions (HG3530, HG3550,

Page 46

ExercisesEN4442EN00EN_0002© 2007 Siemens AGSiemens50Exercises9.7 Check the predefined profiles (SFM and MFM) for the Common Gateway.9.8 Create a Commo

Page 47

SolutionsEN4442EN00EN_0002© 2007 Siemens AGSiemens5110 Solutions Questions10.1 Which boards can be used in a HiPath 4000 V4 as an HG3500?STMI2 Q2316-X

Page 48 - Technical Data HG 3570/3575

SolutionsEN4442EN00EN_0002© 2007 Siemens AGSiemens52Exercises10.7 Check the predefined profiles (SFM and MFM) for the Common Gateway.DISPLAY-BFDAT;10.

Page 49 - Questions

SolutionsEN4442EN00EN_0002© 2007 Siemens AGSiemens5310.9 Create a Common Gateway in mixed modus.RemarksA board with 60 B channels should be used for H

Page 50

SolutionsEN4442EN00EN_0002© 2007 Siemens AGSiemens54

Page 51 - 10 Solutions

OverviewEN4442EN00EN_0002© 2007 Siemens AGSiemens61.2 Hardware and Loadware NCUINew loadware (PZKNCI40) is available for the boards NCUI2+ and NCUI4 i

Page 52 - Gateway

OverviewEN4442EN00EN_0002© 2007 Siemens AGSiemens71.4 Hardware and Loadware HG3500 V4Until HiPath 4000 V3.0 was released, each feature had separate lo

Page 53

OverviewEN4442EN00EN_0002© 2007 Siemens AGSiemens81.6 RestrictionsCQR ViewerThe CQR Viewer application is only supported for HFA (FUNCTION=HG3530) and

Page 54 - Solutions

OverviewEN4442EN00EN_0002© 2007 Siemens AGSiemens91.8 Number of B Channels Dependent On Enabled FeaturesThe following two tables provide an overview o