KINCO 1CONTENTS MT5000/4000 SERIES HMI AND PLC CONNECTING GUIDE...3 SERIAL COMMUNICATION PIN
KINCO 10WH-A93RG0-00E825 WH-A93RG0-00E825 Serial thermal 384 dots/line SP-M, D, E, F SP-E4004SK Serial Stylus micro printer 240 dots/line Downl
KINCO 100Counter(Current Value double word) ------- CCV-32 48-79 DD Timer(Current Value) ------- TCV0-127 DDD Internal Register ------- V0-2047 DDD
KINCO 101 Supported Device Device Bit Address Word Address Format Notes Password ------ APAS 0 H Meter Number ------ ANUM C032 HHHH.H Ini
KINCO 102Series CPU Link Module Parameter Cable Hitachi Inverter SJ300 RS485-2 Setting Your owner cable Communication Setting HMI default c
KINCO 103 ------ P Extend Func 0~50 DD ------ H Extend Func 0~512 DDD ------ F Func Date 0~65535 DDDDD ------ C Func Date 0~65535 D
KINCO 104H-252B(CPU22-02HB) H-252C(CPU22-02HC) H-300(CPU-03Ha) H-302(CPU2-03H) H-700(CPU-07Ha) H-702(CPU2-07H) H-2000(CPU-20Ha) H-2002(CPU2-20H) H-40
KINCO 105MICRO-EH(EH-D64) MICRO-EH(EH-A40) MICRO-EH(EH-D40) MICRO-EH(EH-A20) MICRO-EH(EH-D20) EH-OB232 EH-OB485 System configuration
KINCO 106 Supported Device Hitachi EH-A23DR Device Bit Address Word Address Format Notes External Input X 00.000-5A.095------ HHH.DDD Read OnlyE
KINCO 107Bit Address Word Address PLC address Notes X 00.000-00.047 X 0000-0047 Y 01.000-01.031 Y 0100-0131 WX 000.00-000.03 WX 0000-0003
KINCO 108 Hitachi EH-A23DR RS232 communication cable Hitachi EH-A23DR RS422 communication cable Hollysys Corporation Serial Communication Series
KINCO 109System configuration Series CPU Link Module COMM Type Parameter Cable RS232 on the CPU unit RS232 Setting Your owner cableLM3109 RS
KINCO 11HMI Ethernet terminalRJ45Ethernet Hub or SwitchRJ451 RX+(orange,white)4 BD4+ (bule)5 BD4- (bule,white)2 RX- (orange)3 TX+ (green,white)7 BD
KINCO 110Discrete outputs and image Relay Q0.0-1.7 ------ D.O Internal memory Relay M100.0-7816.7 ------ DDDD.O Analog inputs ------ IW0 D Ana
KINCO 111System configuration Series CPU Link Module COMM Type Parameter Cable RS232 on the CPU unit RS232 Setting Your owner cableHD HD-JZ0
KINCO 112MCU Register ------ VW 0-4094 DDDD Cable Diagram RS232 Port RS485 Port IDEC Corporation Serial Communication Series CPU Link M
KINCO 113Counter(Current Value) ------ C_CV0-99 DD Counter(Preset Value) ------ C_SV0-99 DD Timer(Current Value) ------ T_CV0-99 DD Timer( Preset
KINCO 114Series CPU Link Module Driver KDN-K3 KDN-K304-14AR RS232 on the CPU unit KDN-K3 System configuration Series CPU Link Module COMM Type
KINCO 115Cable Diagram RS232 communication cable RS485 communication cable Kinco Corporation Serial Communication Series CPU Link Module Dri
KINCO 116Analog outputs ------ AQW0-62 DD Internal register ------ VW0-4094 DDDD Internal register(double word) ------ VD0-4092 DDDD N
KINCO 117 RS485 communication cable Kinco ED Series Serial Communication Series CPU Link Module Driver RS232 on the CPU unit ED100 RS485 on port
KINCO 118 Note: If the servo controller station has been modified, the station will take effect until the servo has been restarted, otherwise communi
KINCO 119sub-address is 06, and the number of bits is 20. The addressing diagram of the touch screen is shown as follows: Cable Diagram ECOSTEP RS2
KINCO 12 RS485 ABB AC500:Default communication parameters 9600, 8, none, 1; station No. : 1 RS232
KINCO 120KV-1000 KV-1000 CPU Direct Keyence KV-1000 System configuration Series CPU Link Module COMM Type Parameter Cable KV-16DT KV-16DT CPU D
KINCO 121Extended Data memory ------ EM0-65534 DDDDD Extended Data memory ------ FM0-32766 DDDDD Communication Setting KV-16DT KV-1000 Cable Di
KINCO 122 Koyo Corporation Serial Communication Series CPU Link Module Driver SM24-T RS232 on the CPU unit RS232 on the port1 KOYO DIRECT DL06 D
KINCO 123variable M(C)0-377 ------ OOO Timer Status T(T)0-177 ------ OOO Counter Status C(CT)0-177 ------ OOO Data Register ------ R(V
KINCO 124 Cable Diagram KOYO SM24-T series RS232 communication cable KOYO SM24-T series RS485 communication cable KOYO DL06 series RS232 communicat
KINCO 125Controller PORT215 pin SVGA terminal (male)3 RX2 TX7 GND4 RTS5 CTSHMI terminal9pin D-SUB female/malecom23 TX2 RX5 GND8 TX7 RX5 GNDcom0/com1
KINCO 126Supported Device Please refer to the PLC manual for details. Communication Setting Ktc RS232 communication Ktc RS485-2 communication
KINCO 127 Ktc RS485 communication cable LENZE Inverter Serial Communication Series CPU Link Module Driver Lecom A/B EVF9323-EV RS232 on the CP
KINCO 128 Lecom AB RS485 communication Cable Diagram Lecom AB RS232 communication cable Lecom AB RS485 communication cable
KINCO 129 LS Industrial Systems Co., Ltd. Serial Communication Series CPU Link Module Driver K120S K7M-DR10UE K7M-DR20U K7M-DT30U K7M-DT40U K7M-
KINCO 13Supported Device ABB AC31 Device Bit Address Word Address Format Input bit I00.00-68.15 ------ DD.DDOutput bit O00.00-68.15 ------
KINCO 130RS232 communication RS485 communication K120S KxxxS RS232 communication LG Modbus Rtu RS232 communication
KINCO 131 LG XGT CPU Serial protocol default communication: 115200, 8, none, 1; station number: 0 Note: Only support 115200 buadrate for the protoco
KINCO 132 RS485 PLC software setting 1. Use the LG Master K-cnet driver,software setting as follows,pay attention to the parameter
KINCO 133 2.Use the LG Modbus Rtu driver,software setting as follows,pay attention to the parameter 3. If click “Connect+Write+Run+Monitor Start”, i
KINCO 134 2. Communicating in the OPR mode Supported Device K120S K7M-DR10UE Device Bit Address Word Address Format Notes I/O Relay P0.0-63.f
KINCO 135Communication Relay N_bit 0.0-5119.F ------ DDDD.H Link Relay L_bit 0.0-2047.F ------ DDDD.H Index Relay Z_bit 0.0-127.F ------ DDD
KINCO 136File Register ------ R 0-10239 DDDDD Data Register ------ D 0-10239 DDDDD Communication Register ------ N 0-5119 DDDD Link Register
KINCO 137 K120S K-cnet protocol RS485-2 communication cable LG Modbus Rtu protocol RS485-2 communication cable LG XGT CPU Serial protocol RS232 com
KINCO 138RS232 communication cable RS485 communication cable LUST BUS Inverter Serial Communication Series CPU Link Module Driver CDE34.008 C
KINCO 139 Supported Device Refer to the Controller software for details: DriveManager for c-line drives Cable Diagram Lustbus RS232 communication
KINCO 14ABB AC31 RS485 ABB AC500 port1 RS232 ABB AC500 port2 RS232 Allen-Bradley Serial Communication Series CPU Link Module Driver MicroLog
KINCO 140RS232C port on the Control unit AFP2462 FP2SH AFP2465+(AFP2803,AFP2804, FP2805) Tool port on the Control unit FP3 AFP3462 Tool port on the C
KINCO 141AFPE214322 Tool port on the Control unit Your owner cableRS232C port on the Control unitFP10SH FP10S AFP3462 RS232C Setting Your owner cabl
KINCO 142 Supported Device FP0-C16 Device Bit Address Word Address Format NotesInput(X) Relay Y0.0-12.F ------ DD.H Output(Y) Relay X0.0-12.F --
KINCO 143PLC corresponds to 1.F in the EV5000.Y\R register address, and so on. 2). EV Register address in the touch screen can be set up to 32,767,
KINCO 144 RS422 communication FP3 RS422 programming port: Another module RS422 communication: Memory map Serial Communication Series CPU Link M
KINCO 145BMS005A-MC11 BMS005A-MC11 RS422 on the CPU unit RS422 Setting Your owner cable Communication Setting HMI BMS005A default communication:
KINCO 146Series CPU Link Module Driver RS232 on the CPU unit RS485 on the CPU unit Mitsubishi FX0N/1N/2N Fx0n RS485 Module Mitsubishi FX0N/1N/2N M
KINCO 1472. *1 support multi station System configuration Series CPU Link Module COMM Type Parameter Cable RS232 on the CPU unit RS232 Settin
KINCO 148 RS422 communication Select default parameter for plc
KINCO 149 FX 2n default communication: 9600, 7, even, 1; station: 0 RS232 communication RS422 communication
KINCO 155130-RM 1771-KGM PLC-5 PLC-5/11 PLC-5/20 PLC-5/30 PLC-5/40 PLC-5/40L PLC-5/60 PLC-5/60L Channel 0 CompactLogix 1769-L20 1769-L30 1769-L31 176
KINCO 150 Fx2N-10G/20GM default communication: 9600, 8, even, 1; station: 0 RS232 communication RS422 communication
KINCO 151FX 3u default communication: 9600, 7, even, 1; station: 0 RS232 communication RS422 communication FX Serial RS422 Computer Link default c
KINCO 152PLC Software Setting: Note:Must modify the value of special data register. Set D8120=OXEO9E; D8121=0; D8129=1; Download and PLC restart. Q
KINCO 153 Q00 series default communication: 9600, 8, odd, 1; station: 0 RS232 communication RS485 communication Q00、Q01 PLC communication setting
KINCO 154 Q02 series CPU port communication 1.HMI Default:115200,8,odd,1 2. PLC Station No.:0(one HMI communicate with one PLC) 3.If baud rate is wr
KINCO 155 Q02 series module communication (Choose Mitsubishi Q_QnA (Link Port)) Baud rate, Parity and Station No. are modifiable. PLC Software Sett
KINCO 156 b. click “type” to select “intelligent” c. click “switch setting” and set
KINCO 157 switch content example Switch1 CH1:transmission rate, transmission setting 0BEEH 115Kbps 8 bit 1 bit even Switch2 CH1:communicatio
KINCO 158Supported Device Fx1s Device Bit Address Word Address Format Notes Input Relay X00-17 ------ OO Output Relay Y00-15 ------ OO Au
KINCO 159Special Data Register ------ SD 9000-9599 DDDD ------ FD 4000-6999 DDDD Note: bit devices don’t support batch, but word device can. Fx
KINCO 16Channel 0 Your owner cable MicroLogix 1400 Channel 2 RS232C Setting Your owner cable Channel 0 1770-KF3 2760-RB 1775-KA 5130-RM SLC500 SL
KINCO 160Link register ------ W000-7FF HHH Special data register ------ SD0-2047 DDDD Data register ------ D0-12287 DDDDD Counter ------ CN0-1023
KINCO 161Output Relay Y0000-1FFF ------ HHHH Input Relay X0000-1FFF ------ HHHH Link register ------ W0000-1FFF HHHH Timer(Current Value)------
KINCO 162com0/com1HMI terminal9pin D-SUB female/male2 RX3 TX4 DTR2 TXD1 RXD5 DSR5 GND6 DSR3 GND6 DTR8 CTSController terminal 6pin Mini DIN(male) FX\Q
KINCO 163 Supported Device Device Bit Address Word Address Format Notes Relay CB 00-FF ------ HH Register ------ CD00-FF HH External Re
KINCO 164Modbus RTU RS232 on the CPU unit Modbus RTU Modbus RTU Extend RS232 on the CPU unit Modbus RTU ExtendModbus ASCII RS232 on the CPU
KINCO 165 MODBUS ASCII RS232 communication: 9600, 8, even, 1; station: 1 Modbus UDP network configuration
KINCO 166 Supported Device Modbus RTU Device Bit Address Word Address Format Notes Output Relay 0X1-65535 ------ DDDDD Input Relay (read only)
KINCO 167RS232 communication cable Ethernet communication cable Cross-connection or crossover network cable can be used as communication cable via t
KINCO 168System configuration Series CPU Link Module COMM Type Parameter Cable NX7 NX7 RS232 on the CPU unit RS232 Setting Your owner cable
KINCO 169General Register ------ L_Dword 0-63 DD General Register ------ M_Dword 0-127 DDD Keep Register ------ K_Dword 0-127 DDD Special Register
KINCO 17 SLC500 RS232 communication CompactLogix/ControlLogix RS232 communication
KINCO 170C20H/28H/40H Link I/F on the CPU unit C20PF/28PF C40PF/60PF C120-LK201-V1 C120-LK202-V1 C120 C120F C120-LK201-V1 C120-LK202-V1 CQM1-CPU11
KINCO 171RS232 on the CPU unit Peripheral port on the CPU unit SYSMAC CS1 CS1G-CPU45 CS1G-CPU44 CS1G-CPU43 CS1G-CPU42 CS1G-CPU45H CS1G-CPU44H CS1G-CP
KINCO 172CJ1G-CPU44H CJ1G-CPU43H CJ1G-CPU42H CJ1M-CPU23 CJ1M-CPU22 CJ1M-CPU21 CJ1M-CPU13 CJ1M-CPU12 CJ1M-CPU11 CJ1H-CPU66H CJ1H-CPU65H Peripheral por
KINCO 173 CP1W-CIF01 RS422 communication Note:cp1h switch DIP1—6 all set OFF. NO. Setup contents default status 1 ON: write enable OFF:write disa
KINCO 174 RS422 communication CPM1AH _CPM2AH protocol RS232 default communication: 9600, 7, even, 2; station: 0 Note: Select custom communication
KINCO 175 Omron CJ1M-CPU22 RS232 default communication: 9600, 7, even, 2; station: 0 Note:1.CJ1M switch DIP: sw1, sw2, sw3, sw5, sw8 must be off, bu
KINCO 176Latch Register ------ HR00-99 DD Data Memory Register ------ DM0000-6655 DDDD Link Register ------ LR00-63 DD Auxiliary Memory Register -
KINCO 177 Note: When connecting by the 4-wire method, set DIP1~6 to off. (The dip on the back of option board) Omron CP1H RS485 communication cable
KINCO 178 Supported Device OMRON E5EZ-R3 Device Bit Address Word Address Format Notes 0.0 — 0.A (C0 read only)1.0 — 1.2D (C1) Var iab le ---
KINCO 1797 Setting area1 shift 00 8 Protection value shift 00 Please refer to the communication protocol for details. H indicates hexadecimal
KINCO 18PLC Software Setting a. RSLogix500 software setting Note: Driver: DF1 Full Duplex; Error Detection: CRC. b. RSLogix5000 software setting
KINCO 180 Communication Setting Network Configuration Supported Device Device Bit Address Word Address Format Bit Table B0-65535 —— DDDDD Bit
KINCO 181Editing Macro, please refer to the type table: Register Type N32 Double FN Float DTN Float UTN Float Input Float SetPoint Float Output Floa
KINCO 1821.06 Mode Cable Diagram Ethernet communication cable Cross-connection or crossover network cable can be used as communication cable via the
KINCO 183RS232 on CPU unit RS232 Setting Your owner cableParker Compax3 Parker Compax3 RS485 on CPU unit RS485-2 Setting Your owner cable Commu
KINCO 184 Supported Device Device Bit Address Word Address Format R_Bit 0.0-9999999.31------ DDDDDDD.DD ------ R_Float 0.0-9999.511 DDDD
KINCO 185PMAC Motion Controller Serial Communication Series CPU Link Module Driver PC/104 PC/104 RS232 on the CPU unit PMAC series System conf
KINCO 186common manual and programming command ORD/JOG* 0-9999 DDDD W Run current program RUN 0-9999 DDDD W Halt program HLT 0-9999 DDDD W Note:So
KINCO 187Series CPU Link Module Driver AURORA PVI-6000-OUTD-US-W RS485 on the port Aurora PV System configuration Series CPU Link Module CO
KINCO 188 2. Connect with RJ12 Profibus Slave Serial Communication Series CPU Link Module Driver SIMATIC S7-300/400 ALL CPUs that have the DP po
KINCO 189 Note:Input and Output Modules should match with Master configuration PLC setting Note: you can find eview.gsd in the fieldbus file of EV
KINCO 19Note: Define the new device in the RSLogix5000 before using the register in the HMI. (2) Define Tags and Data type: select “controller tags
KINCO 190(1)make a new project in s7-300 through the guide (2)we must use OB82,OB86,OB100,OB121 and OB122 in BLOCK, or system will go wrong when P
KINCO 191 Note: the address No. of DP master station and slave can not be same. (5)input and output setting (6)Profibus DP Slave has adaption func
KINCO 192 (7) Double click slave ico, then set User_Prm_Data (0) =01 Supported Device Device Bit Address Word Address Format Notes Direct I/O
KINCO 193Direct I/O Input ———— LW8500~8615 DDDD correspond PIWDirect I/O Output ———— LW8000~8115 DDDD correspond PQWDirect I/O Input ———— LW8500
KINCO 194 Supported Device Device Bit Address Word Address Format Notes Bit LB 8999 ------ DDDD ------ LW 8900 DDDD Note: LB8999 means bar
KINCO 195Systems Configuration Series CPU Link Module COMM Type Parameter Cable RS232 on the CPU unit RS232 Setting Your owner cable PCS PCS1.
KINCO 196Flag F0-8091 ------ DDDD Timer ------ T0-1599 DDDD Counter ------ C0-1599 DDDD Register ------ R0-4095 DDDD Register(support single floa
KINCO 197Series CPU Link Module Driver Sailsors D9 Swp-T16-80-08-N RS232 on the CPU unit Sailsors D9 System configuration Series CPU Link Mo
KINCO 198 Schneider Electric, Ltd. Serial Communication Series CPU Link Module Driver Micro TSX3705001 TSX 37 05 028DR1 TSX 37 08 056DR1 TSX 37
KINCO 199Module Type RS232 Setting Your owner cableTSX3705001 TSX3705001 TSX 37 05 028DR1 TSX 37 08 056DR1 TSX 37 10 128DT1 TSX 37 10 128DR1 TSX
KINCO 2Koyo Corporation...
KINCO 20 PLC configuration Supported Device MicroLogix 1200 Device Bit Address Word Address Format Notes Bit data file B10:0.0-254.15 ------
KINCO 200 RS485 communication protocol default communication:9600, 8, even, 1; station: 1. RS232 communication Note: Cable by Schneider Electric In
KINCO 201RS485 communication PLC Setting 1. Sort menu-Æ“modicum telemecanique” Æ “xway driver manager” to set communication parameter 2. Pop-up to
KINCO 202 3. Press ”ok” and pop up the following tips 4. And then click ”xway test”Æ”connect”, if the connection is successfu
KINCO 203 Unitel-way protocol setting: Modbus protocol setting::
KINCO 204 6. Setting up the configuration and download the project to the PLC Schneider Twido Modbus RTU protocol default communication: 19200, 8, n
KINCO 205 Twido Software setting 1. Specify a large number for the internal word in the “controller > memory use >edit” and load the configurat
KINCO 206Internal Relay S00000-32767 ------ DDDDD Auxiliary Relay M00000-32767 ------ DDDDD Data Register Relay MW.B0000-9999.F ------ DDDD.H
KINCO 207Cable recommended by Schneider Electric Industries, Rotary switch setting: 3 (OTHER Direct) Modicon modbus Protocol RS485 PLC software sett
KINCO 208 Supported Device Device Bit Address Word Address Format NotesState instructions(Write Only) Ctrl_Write 184-252 ------ HHH Sequence co
KINCO 20914H SC_L Read PV lower limit side scaling 15H SC_H Read PV higher limit side scaling 16H DPFLG Read 0=show 1=cancel 20H E_PRG Read
KINCO 21Output data file O0:0.0-0.63 ------ DD.DD Input data file I1:0.0-0.63 ------ DD.DD Integer data file ------ N15:0 D Integer data
KINCO 210SIEMENS Serial Communication Series CPU Link Module Driver S7-200 CPU212 CPU214 CPU215 CPU216 CPU221 CPU222 CPU224 CPU226 RS485 on the C
KINCO 211CPU226 Serial System configuration Series CPU Link Module COMM Type Parameter Cable RS232 Setting Your owner cable S7-200 CPU222 C
KINCO 212 RS485 communication Siemens S7-300/400 (PC Adapter) driver protocol 1. If you use adapter to communicate, PLC must be 187.5K. 2. HMI com
KINCO 213 Siemens S7-300/400 (via MPI port) driver protocol 1. This drive only comport the HMI with MPI port. Don’t support indirect online and dire
KINCO 214 PLC software setting S7-200 software setting
KINCO 215 Siemens S7-300/400 (PC Adapter) drive software setting A)Use adapter from eview corporation. MPI transmission rate must be set 187.5k. If t
KINCO 216 C)After Setting, download project into PLC. Make sure the MPI port’s transmission rate is 187.5k, and select” PC Adapter(MPI)” in “set PG/P
KINCO 217 Siemens S7-300/400 (via MPI port) drive software setting 1. PLC station No. can be 0~15. 2. MPI baud rate can be 19.2k or 187.5k. Etherne
KINCO 218 PLC configuration The settings for the CP 243-1 are defined in STEP 7 Micro/WIN via the Ethernet Wizard. For assistance with all the inform
KINCO 219z Identify or enter the module position “ZERO”. z Click on “Next”. 3. Specifying IP address z Define an IP address for the CP 243-1. Cau
KINCO 22Integer data file ------ N11:0-255 DDD Integer data file ------ N10:0-255 DDD Integer data file ------ N7:0-255 DDD Integer data f
KINCO 220 5. Configuration connection z The configuration for connecting the CP 243-1 to the panel must be defined as in Fig.. z Click OK to confi
KINCO 221 7. Assigning memory z Specify a memory area for the configuration of the CP 243-1. Recommend: If you click on Suggest address, the Wizard
KINCO 222 9. Confirm message z Click “Yes” to confirm the message that appears. 10. Call ETH0_CTRL z In your STEP 7 Micro/WIN program, you must
KINCO 223Discrete inputs and image Relay I.B0.0-32768.7 ------ DDDDD.O Analog Outputs ------ AQW0-62 DD Analog Inputs ------ AIW0-62 DD SCR doubl
KINCO 224Internal assistant node M 0.0~2047.7 ------ DDDD.O Data Register Relay node DBm.DBX 0~8192.7------ DDDD.O m 10-60 Data Register Relay ---
KINCO 225 If the PC Adapter with the following RS232 cable, it must add a connection line for communicating with touch-screen 2. Long distance commu
KINCO 226a. cross-ruling cable diagram: b. cross-over cable cable diagram: HMI Ethernet terminalRJ45Ethernet Hub or SwitchRJ451 RX+(orange,white)4 B
KINCO 227RS232 RS485 Supported Device Device Bit Address Word Address FormatInput Relay(receive external switch signal) X0-377 ------ OOO Out
KINCO 228Counter(Current value) ------ C_Current_Word 0-199 DDD Counter ------ C_Current_Double 200-255 DDD Timer(Preset value) ------ T_Preset_Wo
KINCO 229Communication Setting Default communication: 9600, 8, none, 1; station: 1 Supported Device Please refer to TMCL Reference Manual for devic
KINCO 23 PLC-5 RS232 cable diagram com23 TX2 RX5 GND8 TX7 RX5 GNDcom0/com1HMI terminal9pin D-SUB female/male2 TXD3 RXD4 RTS7 SG5 CTS6 DSRController t
KINCO 2302.0-2.19 RFS ------ DWord 0.0-2.2 DD.D Write OnlySIO 0-7 ------ D Write OnlyGIO 0.0-0.10 2.0-2.07 1.0-1.7 DDD.DD Read OnlyCALC ------
KINCO 231 Supported Device Device Bit Address Word Address Format Notes Internal Relay M0~M7999 ------ DDDDD Input Relay X0.0~X51.1 ------
KINCO 232Y0~Y511 0X18433~0X 18762 S0~S1023 0X20481~0X21504 M8000~M8511 0X24577~0X25088 T0~T618 0X25601~0X26219 C0~C634 0X27649~0X28283 Register Area:
KINCO 233TRIO Euro Euro 205x RS232 on the CPU unit Modbus RTU Extend System configuration Series CPU Link Module COMM Type Parameter Cable RS23
KINCO 234 Controller internal setting: Modbus protocol default communication: 9600, 8, even, 1; station: 1 RS232 communication RS485-4 communicat
KINCO 235 Trio controller communication settings Omron protocol: define Host Link slave node HLS_NODE=1 define Host Link slave mode code HLS_MODEL=$
KINCO 236Data register ———— 4X 0-1023 DDDDD Note: Address correspondence: 4x corresponds to VR; 4x_bit corresponds to VR’s bit. Address differen
KINCO 237 System configuration Series CPU Link Module COMM Type Parameter Cable VH VH-14MR RS232 on the CPU unit RS232 Setting Your owner
KINCO 238Cable Diagram VH-14MR RS232 communication cable 1. Communication via USB programming port Connection with HMI by programming cable of Vigor
KINCO 239 Supported Device Device Bit Address Word Address Format Notes Addr communication parameter ------ Addr HHHH A FWD ------ A 0 D
KINCO 24HMI Ethernet terminalRJ45Ethernet Hub or SwitchRJ451 RX+(orange,white)4 BD4+ (bule)5 BD4- (bule,white)2 RX- (orange)3 TX+ (green,white)7 BD
KINCO 240Yamatake Corporation Serial Communication Series CPU Link Module Driver DCP30 P30A2 RS485 on the CPU unit Yamatake DCP30 SDC35/36
KINCO 241 DMC RS485 default communication: 19200, 8, even, 1; station: 6. Plc 设置 1. Set modbus RTU in the SLP-D10, and then download. 2. Station m
KINCO 242Supported Device DCP30 Device Bit Address Word Address(Parameter code) Format Notes RUN Status ------ 1-26 DDD PARA ------ 1-33 DD
KINCO 243When connecting multiple instruments, for distinguishing instruments, each instrument must be set C84 value with a different parameter. . 3、
KINCO 244Cable Diagram DC30 RS485 communication cable RS232 communication,need to use RS-232 to RS-422/485 converter SDC36 RS485 communication
KINCO 245Yaskawa Inverter Serial Communication Series CPU Link Module Driver V RS485 on the CPU unit Yaskawa AH Modbus RTU System configurati
KINCO 246Simulant input data register ------ 3X1-65535 DDDDD data register ------ 4X1-65535 DDDDD Node: this drive can not provide write batch
KINCO 247 PLC Attribute※ (station is not necessary) Network configuration※ (Note:IP and port must be set correct, that is set as MPE720 software.)
KINCO 2481. set the IP,connect with the MPE720 software 2. how to set the IP
KINCO 249 Change, save, and save to flash: Restart the controller and the set is ok. If online, then you can monitoring the data: Monitor single da
KINCO 25Device Bit Address Word Address Format Notes Linear Deceleration(LD) ------ LD 0~3 D R/W Linear Acceleration(LA) ------ LA 0~3 D R/
KINCO 250 Supported Device Device Bit Address Word Address Format Notes Input register node IB0000.0-FFFF.F ------ HHHHH.H Output register node
KINCO 251HMI Ethernet terminalRJ45Ethernet Hub or SwitchRJ451 RX+(orange,white)4 BD4+ (blue)5 BD4- (blue,white)2 RX- (orange)3 TX+ (green,white)7 B
KINCO 252 Cable Diagram MP2300 RS232 communication cable Yaskawa SGDM (Servo Controller) Serial Communication Series CPU Link Module Driver RS
KINCO 253Communication Setting Default communication: 9600, 7, even, 1; station: 0 RS232 communication RS422 communication Supported Device Devic
KINCO 254Cable Diagram RS232 communication cable RS422 communication cable YuDian AI Serial Communication Series CPU Link Module Driver AI-518
KINCO 255Communication Setting RS485 default communication: 9600, 8, none, 1; station: 1 SPECIAL NOTE: For example: If station number is 2, register
KINCO 256dIH ------ 14 0EH -1999~+9999 DD ALP ------ 15 0FH 0~9999 DD Sc ------ 16 10H -1999~+4000 0.1℃ DD Op1 ------ 17 11H 0~48 DD oPL ------
KINCO 257 AI-7048 Device Bit Address Word Address Format Notes PV ------ 0.0-3.0 D.D Read only SV ------ 0.0-3.0 D.D Reference ------ 0.0-3
KINCO 258this controller, other controller can’t use address 5~8. Cable Diagram RS485 communication cable RS232 communication,need to use RS-232 to
KINCO 26System configuration Series CPU Link Module COMM Type Parameter Cable ADAM-4017 RS485on the CPU unit RS485 Setting Your owner cableADAM
KINCO 27 Set OK, then Update. Supported Device ADAM-4017 Device Bit Address Word Address Format Read Analog Input form Channel N ——— S_Channel 0-6
KINCO 28 255(FF):0-7 channel show. 127(7F):0-6 channel show, 7 Channel does not show. ADAM-4015 Device Bit Address Word Address Form
KINCO 29 Supported Device Device Bit Address Word Address Format Notes control CTL (0~5)&128&150 ------ DDD Write onlyset ------ SET (0
KINCO 3MT5000/4000 Series HMI and PLC connecting guide Serial Communication Pin definition Pin assignment of the 9-pin male, D-SUB, COM0/COM2. This p
KINCO 30 Communication Setting PLC software setting Use the guide of the Workbench software
KINCO 31 Supported Device (Only data of comms can be monitored, some address greater than or equal to 100 are read only. Please pay attention to mat
KINCO 32 Barcode Serial Communication Series CPU Link Module Driver Barcode 3800LTP-12E RS232 Barcode System configuration Series CPU Link
KINCO 33Baumuller Serial Communication Series CPU Link Module Driver Baumuller BM4413-ST0-02200-03 RS422 on the CPU unit Baumuller System confi
KINCO 34HMI terminal9pin D-SUB female\maleController terminal9 pin D-SUB (male)6 RXD+1 TXD-3 GND5 RXD-9 TXD+com0/com19 TXD+4 TXD-6 RXD+1 RXD-5 GND
KINCO 35STW1 close, positive rotation. STW1 open, negative rotation. STW2 REV inching turning. STW3 FWD inching turning. Set frequency ------ HSW 0 D
KINCO 36 Communication Setting PPC-R communication setting RS232 communication: 19200, 8, even, 1; station number: 128 RS485 communication Note: To
KINCO 37 Note: To communicate with the touch screen, declare variable firstly in the Rexroth software. L40 Hardware Settings PLC Software Settings
KINCO 38 1.Click”scp configurator”--->”scanning ”or” add device”--->”next”, pay attention to the default controller IP: 192.168.1.1. And set IP
KINCO 39 4. Click “online/login” L40 software setting 1) The IndraLogic software connect with the Rexroth IndraControl L40 by ethernet cable(test: p
KINCO 4HMItek Ltd. will continuously provide drivers for various brands of printers. Note: The maximum distance of printer cable is 5m. Pin assignmen
KINCO 40 Note:Must select Download symbol file Click “OK” and pop-up the window as follows: And then edit program: Input B0 and pop-up the dialog,
KINCO 41And set up coil: At the same time, you will find that there automatically generate two variables in the global variable: Then setting as fo
KINCO 42 Setting communication parameter: Then click “Login”: Communicating successfully, you can operate(“Online” menu to select “run” or others):
KINCO 43 Note:The PLC panel must be set up, press” Enter”, then press”△”, until showed up “ RS232”, and then press ”Enter” to enter “COM
KINCO 44L40 communication cable Bosch Rexroth Ethernet Network communication (indirect online and direct online simulation disable) Series CPU L
KINCO 45 PLC Attribute※ (station disable) Network configuration※ (Note: PLC port num. must be set 6042,HMI port num. is optional,default is 6042. I
KINCO 46Note: To communicate with the touch screen, declare variable firstly in the Rexroth software. PLC software setting PLC connect with PC by cro
KINCO 47 2. “”resource”--->“Global variables”--->declare variable in “HMI” 3. Click “online/login” Supported Device Device Bit Address Word
KINCO 48 b. crossover network cable diagram: HMI Ethernet terminalRJ45Ethernet Hub or SwitchRJ451 RX+(orange,white)4 BD4+ (blue)5 BD4- (blue,white
KINCO 49HMI Note: Baud Rate and Station No. must be the same as the setting in the controller. PLC setting Note: you can find MT5020.EDS in fieldbu
KINCO 513579111315172110STBDATA1DATA2DATA3DATA4DATA5DATA6DATA7DATA8BUSYGND541383127211104ERROR1514300 series HMI15 pin portPrinter 26 pin portNote:th
KINCO 50 2. Copy “MT5020.EDS” to “C:\Program Files\Common Files\CAA -Targets\ StepServo\ PlcConf” 3. Configuration setting a. run codesys software,ma
KINCO 51 c. set Baud Rate d. choose “CanMaster” right click “Append HMI-MT5020” e. Node ID: set slave station No.
KINCO 52 f. in the “Library Manager” we import “3S_CANopenMaster.lib” g. PDO read and write setting
KINCO 53 h. define Global Variable i. SDO setting,this step need program
KINCO 54 j. load the configuration into the PLC Supported Device Device Bit Address Word Address Format Notes ———— LW8000~LW8999 DDDD Note: w
KINCO 55Danfoss Inverter Serial Communication Series CPU Link Module Driver Danfoss FC-300 RS485 on the CPU unit Danfoss Modbus RTU System conf
KINCO 56 Note:Change the value of 8-30 to 2 on the Danfoss Frequency Converter for modbus protocol(Change the value of 8-30 to 0 for the Danfoss Prot
KINCO 57RAM Register(Double Word) ———— RMD0-7998.99999 DDDD.DDDDDRAM Register ———— RMW0-7998.99999 DDDD.DDDDDNote: 1. D indicates decimal; the pre
KINCO 58 ◆Control word RW1: While RW1=0x47C or 1148, it means start. While RW=0x0F03 or 3843, it means stop. ◆Frequency of RW0 mappin
KINCO 59Input bit (read only) 1X1-65535 ------ DDDDD Input Register (read only) ------ 3X1-65535 DDDDD Output Register ------ 4X1-65535 DDD
KINCO 6a. WH4008A31-053 Serial port printing mode, pulling up W1 short circuit block by RS232 level. b. WH-A62R10 support printing of 190 dots widt
KINCO 60 Set 0X 3,0X 4,0X 5,0X 6,0X 7 all to “1” via the method of setting on when window open; Change the frequency inverter status (start or stop)
KINCO 61HMI terminal9pin D-SUB female\maleController RS485 terminal696861com0/com11RX-6RX+5 GND Delta Corporation Serial Communication Series CPU
KINCO 62 DVP RS485-2 communication Note: if we use RS485 communication, we should change the value of D1120 in the PLC Software. PLC setting 1. Wp
KINCO 63 2. when PLC and Wpl207 are connective, change D1120. for example, 9600,7,even,1.and then D1120=86(HEX) Supported Device Device Bit Address
KINCO 64 Delta (Temperature Controller) Serial Communication Series CPU Link Module Driver DTA4848 RS485 on the CPU unit DVP DTB9696VR RS485 o
KINCO 65Device Bit Address Word Address Format Notes Output bit 0X1-65535 ------ DDDDD Input bit (read only) 1X1-65535 ------ DDDDD Inpu
KINCO 66range. In the setting mode 4707H Lower-limit of temperature range The data content should not be lower than the temperature range. In the s
KINCO 674729H AT Setting OFF: 0 (default), ON: 1. in the adjusting mode 4733H CT monitor value Unit is 0.1A. in the running mode DTB9696VR:Add
KINCO 68100FH The setting of Dead band when Dual Loop output control are used -999 ~ 9,999. in the adjusting mode 1010H Hysteresis setting value of
KINCO 69In the setting mode 1024H Upper-limit alarm 1 In the setting mode unit: 0.1 1025H Lower-limit alarm 1 In the setting mode 1026H Up
KINCO 7 4. Parallel Printer Cable of EPSON/HP Printer
KINCO 700810H Communication write-in selection Communication write in disabled: 0 (default), Communication write in enabled: 1. In the setting mo
KINCO 71D3CellTM Serial Communication Series CPU Link Module Driver D3CellTM D3CellTM RS422 on the CPU unit DLoadCell System configuration Seri
KINCO 72 EB-MOD2P-01(Bus Bridge) Serial Communication Series CPU Link Module Driver RS232 on the CPU unit RS485 on the CPU unit FieldBus Bridge EB
KINCO 73 EB-MOD2P-01 RS485-2 communication Supported Device EB-MOD2P-01 Device Bit Address Word Address Format Notes Internal/External Output
KINCO 74 Note:The correspondence between the device of EV5000 and the s7-300 software, as follows: 4X-DINV------------PID e.g.:4X-DINV1------------
KINCO 75 (3)After press “ok”, and then give a connection as follows: Note: the address of DP can’t be the same as MPI’s .Double click the address n
KINCO 76 Note: for project configuration of BRIDGE, you must configure DI/D0 resource of 12 bytes firstly. AI/AO is optional. (5)Must Use OB82,OB86
KINCO 77ON OFF ON 38400 OFF ON ON 57600 ON ON ON 115200(5)Setting station number of modbus by switching DIP4-8 of modbus ID port ,support 1 to 30 kin
KINCO 78ENDA Serial Communication Series CPU Link Module Driver ELC RS485-2 on the CPU unit ETC RS485-2 on the CPU unit EUC RS485-2 on the CPU
KINCO 79Output Register ------ MW 0-65535 DDDDD Input Register (read only) ------ IR 0-65535 DDDDD ENDA Controller Devices Device Bit Addre
KINCO 8 Printer series 25 pin convert to 15 pin of the MT4300 series touch screen
KINCO 80Emerson Ec10 RS232 communication Emerson Ec20 RS232 communication Emerson Ec10 RS485-2 communication Emerson Ec20 RS485-2 communication
KINCO 81 Note: Communication with port1, you must set the system configuration in the programming software first. Supported Device
KINCO 82Emerson Ec10 Device Bit Address Word Address Format Notes Output Relay X000-377 ------ OOO Input Relay Y000-377 ------ OOO Int
KINCO 83 Emerson RS485-2 communication Epower Serial Communication Series CPU Link Module Driver EPower Epower Epower CPU Direct Epower Sla
KINCO 84 Supported Device Device Bit Address Word Address Format Notes UPSSet UPSSet1-6 ------ DDDDD UPSPanel UPSPanel0-9 ------ DDDDD UPSDat
KINCO 85Slave driver notes: 1. Transmit the device value to LW, LB by timer; refer to the addr table for details. 2. UPSCommand must use with UPSSe
KINCO 86Supported Device Device Bit Address Word Address Format Notes B0 - 8999 ------ DDDD ------ W0 - 8999 DDDD Communication Setting
KINCO 87 Facon Corporation Serial Communication c CPU Link Module Driver RS232 on the CPU unit Port 0 Port 1 FBS-CB25-3 Port 2 FBs FBs-10MA/MC
KINCO 88Communication Setting FACON FB RS232 communication FBS-CB25-3 module RS485 communication FBS-CB25-3 module communication Modbus RTU RS232 c
KINCO 89 Modbus RTU RS485-2 communication Note: The detailed communication configuration must be the same as the PLC’s port setting. Supported Dev
KINCO 9 5. Recommend Optional printer Printer Driver Printer model Interface Print Structure Print format EPSON ESC/P EPSON ME30 USB inkje
KINCO 90Double word Counter Register ------ DRC200-255 DDD Note:HR register corresponds to the “R” register of the PLC; DR register corresponds to
KINCO 91 Fuji SPB Serial Communication Series CPU Link Module Driver SPB NW0P20T-31 RS485 interface on the CPU NB NB2U24R-11 RS485 interface
KINCO 92Supported Device SPB Device Bit Address Word Address Format NotesData register D 0~6FF.F ------ HHH.H Special relay M_special 0~1FF --
KINCO 93Data register ------ DW 0~3F HHH Special register ------ DW_special 0~1FF HHH Cable Diagram GE Fanuc Automation Inc. Serial Communicat
KINCO 94IC693CPU340 IC693CPU341 IC693CPU350 IC693CPU360 IC693CPU364 Connector on Power Supply Port1 on CPU unit Port2 on CPU unit IC693CPU351 IC693CP
KINCO 95 GE Fanuc Series SNP RS422 Communication GE SNP-X Protocol RS232 Communication GE SNP-X Protocol RS422 Communication
KINCO 96 Note: Set matching communication parameter in the Programming software. Supported Device Device Bit Address Word Address Format
KINCO 97Cable Diagram GE Fanuc Series SNP RS232 communication The communication cable recommended by GE Fanuc Automation VersaMax series RS232 commun
KINCO 98 90-30/VersaMax RS422 communication HAIWELL Serial Communication Series CPU Link Module Driver RS232 on com1 E/S HW-S16ZA220R RS485 on
KINCO 99Communication Setting Haiwell RS232 communication Haiwell RS485 communication Supported Device Device Bit Address Word Address Format N