4. Clear Text Display Module & System Parameters English
© STÖBER plc 1997
25
05.02.01
Parameter Function Range
[Default]
Description / Notes
P123
Enable/disable JOG button 0 - 1
[1]
0 = JOG button disabled.
1 = JOG button enabled (only possible if P007 = 1).
P124
Enable/disable and buttons
0 - 1
[1]
0 = and buttons disabled.
1 = and buttons enabled (only possible if P007 = 1).
Note: This applies for frequency adjustment only. The buttons can
still be used to change parameter values.
P125
Reverse direction inhibit 0 - 1
[1]
0 = Reverse direction disabled. Inhibits reverse commands from
ALL sources (reverse RUN commands result in forward rotation)
1 = Normal operation (FORWARD/REVERSE operation allowed)
P131
Frequency setpoint (Hz)
0.00 -120.00
[-]
P132
Motor current (A)
0.0 - 99.9
[-]
P134
DC link voltage (V)
0 - 1000
[-]
P135
Motor RPM
0 - 40000
[-]
P137
Output voltage (V)
0 - 1000
[-]
P140
Most recent fault code 0 - 9999
[-]
The last recorded fault code (see section 5) is stored in this
parameter. It is cleared when the inverter is reset.
This is a copy of the code stored in P930.
P141
Most recent fault code -1 0 - 9999
[-]
This parameter stores the last recorded fault code prior to that stored
in P140/P930.
P142
Most recent fault code -2 0 - 9999
[-]
This parameter stores the last recorded fault code prior to that stored
in P141.
P143
Most recent fault code -3 0 - 9999
[-]
This parameter stores the last recorded fault code prior to that stored
in P142.
P151
Green LED function 0 - 5
[4]
0 =Off
1 =On
2 = Fault mode: On = Tripped
Flashing = Warning
3 = Running mode:On = Motor running
Flashing = Inverter on but motor
stationary
4 = Default mode (see table in section 3.6)
5 = Not used
P152
Yellow LED function 0 - 5
[5]
0 =Off
1 =On
2 = Fault mode: On = Tripped
Flashing = Warning
3 = Running mode:On = Motor running
Flashing = Inverter on but motor
stationary
4 = Not used
5 = Default mode (see table in section 3.6)
P201
PI closed loop mode 0 - 2
[0]
0 = Normal operation (closed loop control disabled).
1 = Not used
2 = Closed loop control using PI input for transducer feedback.
P202
P gain (%) 0.0 - 999.9
[1.0]
Proportional gain.
Read-only parameters. These are copies of the values selected
by P001 but can be accessed directly via the serial link.