English 4. Clear Text Display Module & System Parameters
© STÖBER plc 199
05.02.01
24
Parameter Function Range
[Default]
Description / Notes
P093 •
••
•
Serial link timeout (seconds) 0 - 240
[0]
This is the maximum permissible period between two incoming data
telegrams. This feature is used to turn off the inverter in the event of a
communications failure.
Timing starts after a valid data telegram has been received and if a
further data telegram is not received within the specified time period,
the inverter will trip and display fault code F008.
Setting the value to zero switches off the control.
P094 •
••
•
Serial link nominal system
setpoint (Hz)
0 - 120.00
[50.00]
Setpoints are transmitted to the inverter via the serial link as
percentages. The value entered in this parameter represents 100%
(HSW = 4000H).
P095 •
••
•
USS compatibility 0 - 2
[0]
0 = Compatible with 0.1 Hz resolution
1 = Enable 0.01 Hz resolution
2 = HSW is not scaled but represents the actual frequency value to
a resolution of 0.01 Hz (e.g. 5000 = 50 Hz).
P099 •
••
•
Communication adapter type 0 - 1
[0]
0 = Option module not present
1 = PROFIBUS module (enables parameters relating to PROFIBUS)
P101 •
••
•
Operation for Europe or USA 0 - 1
[0]
This sets the inverter for European or USA supply and motor
frequency:
0 = Europe (50 Hz)
1 = USA (60 Hz)
Note: After setting P101 = 1 the CombiDrive
®
must be reset to
factory defaults. i.e. P944 = 1 to automatically set P013 =
60 Hz, P022 = 60 Hz, P081 = 60 Hz, P082 = 1680 rpm and
P085 will be displayed in hp.
P111
Inverter power rating (kW/hp) 0.0 - 10.00
[]
Read-only parameter that indicates the power rating of the inverter in
kW. e.g. 0.55 = 550 W
Note: If P101 = 1 then the rating is displayed in hp.
P112
Inverter type 1 - 8
[8]
Read-only parameter.
1 = MICROMASTER series 2 (MM2)
2 = CombiDrive
®
3 = MIDIMASTER
4 = MICROMASTER Junior (MMJ)
5 = MICROMASTER series 3 (MM3)
6 = MICROMASTER Vector (MMV)
7 = MIDIMASTER Vector (MDV)
8 = CombiDrive
®
series 2
P113
COMBIMASTER model 24 - 29
[-]
Read-only parameter.
24 = CM150/3
25 = CM220/3
26 = CM300/3
27 = CM400/3
28 = CM550/3
29 = CM750/3
P121
Enable/disable RUN button 0 - 1
[1]
0 = RUN button disabled.
1 = RUN button enabled (only possible if P007 = 1).
P122
Enable/disable
FORWARD/REVERSE button
0 - 1
[1]
0 = FORWARD/REVERSE button disabled.
1 = FORWARD/REVERSE button enabled (only possible if P007 = 1).