11/01 Installing and Connecting the Panel PC 670/870
SIMATIC Panel PC 670/870 Commissioning Instructions 1–5
A5E00135748-01
Installation
The operating unit can be mounted in the installation cut-out either with clamp
saddles or screw mountings. Fixation using screw mountings is not possible for the
12” touch screen model.
Fixation using clamping saddles, in conjunction with a continuous seal, meets the
requirements for IP65 Degree of Protection.
Installations using bolts meet the IP 54 Degree of Protection.
Installation positions and dimensions
The permissible installation positions are dependent on the Panel PC type
installed.
Schraubbefestigung und Dichtungsbereich
Panel PC 670/870, 12", Tasten
Panel PC 670/870, 15", Tasten
Panel PC 670/870, 12", Touch
Panel PC 670/870, 15", Touch
L4 L5 A1 A2
465
465
235
279
16
16
10
17
465
235
16
16
10
10
Befestigungsspannbügel mit
Gewindestiften
Druckpunkte für
Befestigungsspannbügel
Vorderseite: Dichtungsbereich bzw.
Rückseite: Bereich für Befestigungsspannbügel
Im Dichtungsbereich
A1 ± 1
A2 ± 1
R
z
120
A
lle Angaben in mm.
L4 ± 0,2
L5 ± 0,2
Figure1–4 Dimensions for Installation of the Operating Unit
All figures in mm.
Threaded
clamping saddle
Pressure points fo
clamping saddle
Front side: seal area
Rear side: clamping saddle area
Within the seal area
Screw Mounting and Sealing Area
Keys
Keys
Page view 12
1 2 ... 8 9 10 11 12 13 14 15 16 17 18 ... 41 42

Comments to this Manuals

No comments