6 PLC Signals 11.90
6.9 Description of the function blocks (FB)
6.9 Description of the function blocks (FB)
The function blocks for tool management, integrating auxiliary axes and workshop UMS are
described in the associated planning guides.
6.9.1 Function block FB 11
EINR-DB
D, KY-
D, KF-
$ FW 246-
$ FW 248-
DBAN
DWNR
DBAN
DWNR
%2 . . DB No. is greater than 255
%3 . . Specified DW No. less than 0
%4 . . Length of DBs to be created not equal to DBs
in the PLC
%5 . . Memory area for DBs in the PLC not large enough
%6 . . DW number specified greater than 255
%7 . . DB 0 cannot be created
Meaning of error numbers in Accu 2
Parameter description of function block FB 11
DBAN DB number and quantity of data blocks to be created.
High byte: DB No.
Low byte: Quantity of data blocks (at least 1).
DWNR No. of the last DW up to which the DB is to be created.
6.9.2 Function block FB 60
BLOCK-TR
D, KY -
D,,KF -
D, KY -
$FW 254 -
$FW 250 -
$FW 252 -
DBQZ
DWQ
DZ/A
DBQZ
DWQ
DZ/A
Meaning of error numbers in Accu 2
%1 . . Quantity of DW to be transferred is greater than
128
%2 . . Quantity of DW to be transferred = 0
%3 . . Source DB missing
%4 . . Destination DB missing
%5 . . Destination DB is too short
%6 . . Destination DB in the EPROM
%7 . . Source DB is too short
Parameter description of function block FB 60
DBQZ No. of the source and destination DBs
High byte: source DB Low byte: destination DB
DWQ No. of the first data word in the source DB
DZ/A No. of the first data word in the destination DB/quantity of data words to be copied
6-20
Siemens AG 1990 All Rights Reserved 6ZB5 410-0DM02