MC35i Terminal Hardware Interface Description
Confidential / Released
s
MC35i_T_HD_v02.00a Page 33 of 42 16.02.2007
Table 17: On-board operating temperature of built-in MC35i module
Parameter Min Typ Max Unit
Normal operation
-20 +25 +70 °C
Automatic thermal shutdown
1)2)
-25 --- >+80 °C
Table 18: Ambient operating temperature of MC35i Terminal according to IEC 60068-2 (without forced
air circulation)
Parameter Min Typ Max Unit
Normal operation
-20 +25 +55 °C
Restricted operation
3)
-25 to -20 --- +55 to +60 °C
Automatic thermal shutdown
1)2)
-25
---
+60
°C
1
When an emergency call is in progress automatic thermal shutdown is deferred. See also
Chapter 3.5.1.5.
2
Due to temperature measurement uncertainty, a tolerance of ±3°C on these switching thresholds
may occur.
3
Restricted operation according to 3GPP TS 45.005 V6.7.0 (2004-11), Annex D, D.2.1,
Temperature (GSM 400, GSM 900 and DCS 1 800): “Outside this temperature range the MS, if
powered on, shall not make ineffective use of the radio frequency spectrum. In no case shall the
MS exceed the transmitted levels as defined in 3GPP TS 45.005 for extreme operation.”