AT Command Set
MC35_ATC_01_V05.00 Page 75 of 256 15.07.2002
4.9 AT+CCWA Call waiting
Test command
AT+CCWA=?
Response
+CCWA: (list of supported <n>s)
OK/ERROR/+CME ERROR
Parameter
See write command
Read command
AT+CCWA?
Response
+CCWA: <n>
OK/ERROR/+CME ERROR
Parameter
See write command
Write command
AT+CCWA=
[<n>,[<mode>
[,<class>]]]
This command controls the Call Waiting supplementary service according to
GSM 02.83. Activation, deactivation and status query are supported.
Response
If <mode>=2 and command is successful
+CCWA: <status>, <class1><CR><LF>
+CCWA: <status>, <class2><CR><LF>...
OK/ERROR/+CME ERROR
Parameters
<n> Sets/shows the presentation mode of URC in the TA
0 disable
1 enable
<mode> When <mode> is not given, network is not interrogated.
0 disable
1 enable
2 query status
<class> Sum of integers each representing a class of information (de-
fault 7). Specifies the class of the active call.
1 voice
2 data
4 fax
7 voice, data and fax (1+2+4)
8 SMS
16 data circuit sync
32 data circuit async
64 dedicated packet access
128 dedicated PAD access
<status> 0 not active
1 active
Unsolicited Result
Code
If <n>=1 and the Call Waiting service is enabled the following URC indicates a
waiting call to the TE:
+CCWA: <number>,<type>,<class>,,<CLI validity>