2.2. Connector RJ-11 for Connection of the Two-Wire
UART.
It is used for connection of the accessories to ASC1 TC65. The signals are not isolated from
the common wire of the GSM module and Terminal housing.
4.GND
3.TX/b 2.RX/a
1.+5V
Fig. 2.3
Table 2.2
Cont. Interface Signal Direction Purpose
1 +5V (DC @<200mA) Term. -> Accessories Power supply of the
accessories
RS485 “a” (D+) <-> different. Input/output RS485 not
inverted
RS232 RxD Term. -> Accessories Transmitter output
RS232 (>+/-6V)
2
LVUART Rx Term. -> Accessories Transmitter output
LVUART (TTL 3.3V)
RS485 “b” (D-) <-> different. Input/output RS485
inverted
RS232 TxD Accessories -> Term. Receiver input
RS232 (>+/-3V)
3
LVUART Tx Accessories -> Term. Receiver input
LVUART (TTL 3.3V)
4 Common for the control assembly
(housing)
Common wire