Accessories
7.1 Reactor and filter
Power Module PM240
Hardware Installation Manual, 07/2009, A5E00807525B AD
95
7.1.4 Sine-wave filter
Installing the sine-wave filter as base component
The sine-wave filters for Power Modules with a rated power (HO) up to 11 kW are designed
as base components. The sine-wave filter is attached to the mounting surface and the Power
Module is mounted directly on the sine-wave filter. The cables to the Power Module are
already connected to the sine-wave filter. The sine-wave filter is connected to the motor
through terminals.
0
0RWRU
/LQH
0RXQWLQJ
VXUIDFHRU
FDELQHWZDOO
&RQQHFWLRQ
FDEOH
6LQHZDYH
ILOWHU
3RZHU0RGXOH
8
9
:
3(
8
9
:
3(
8
9
:
3(
Figure 7-8 Connecting the sine-wave filter as base component
The overall and mounting dimensions of the sine-wave filter are written in the technical
specifications.