Siemens SIMATIC NET PROFIBUS User Manual Page 9

  • Download
  • Add to my manuals
  • Print
  • Page
    / 24
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 8
9
PROFIBUS
Hybrid cables
DESINA and ECOFAST
The ECOFAST and DESINA systems
are an open system solution in the
innovative area of distribution without a
control cabinet. They set new stan-
dards for equipping machines and
plants with automation, switch and
drive components. The basis is fully
distributed installation and direct
machine assembly of the units.
All automation, drive and installation
components are combined to make an
integrated total solution with standard-
ized cables and connections for data
and power.
There is a user-friendly configuration
tool to help design the power engineer-
ing for the plant.
In a hybrid cable, copper cables and
fiber optic cables are contained in one
cable. The fiber optic cables in this
case are plastic FOCs.
This means that by using hybrid
cables the data and the power supply
can be transferred together with one
cable.
The line-type power supply for the
consumers uses a power bus.
Communication via standardized field
buses and uniformly standardized
interfaces make DESINA and
ECOFAST an open, manufacturer-inde-
pendent and flexible system solution.
DESINA is the brand name for DEcen-
tralized and Standardized INstallAtion
technology for machine tools;
ECOFAST stands for Energy and
COmmunication Field InstAllation
sySTem.
Hybrid cables mean a reduction in
overall costs from planning stage to
standard production by:
· Reducing configuration times,
cabling expenditure, the number of
versions and machine downtimes
· Shorter assembly and commission-
ing times
· Better plant availability thanks to
shorter service times
· Less floor space required for
machines and installations
· Greater flexibility
· Increased availability through
diagnostics
DESINA hybrid cable
The rugged hybrid cable approved for
trailing contains two plastic FO cables
for data communication and four cop-
per wires (1.5 mm
2
) to supply power to
DESINA nodes.
The DESINA hybrid cable is particularly
suitable for connecting locally installed
DESINA components.
ECOFAST hybrid cable
The rugged hybrid cable approved for
trailing contains two copper wires for
data communication and four copper
wires (1.5 mm
2
) to supply power to
ECOFAST nodes.
Figure 11: DESINA Hybrid Cable
Figure 12: ECOFAST Hybrid Cable