Siemens AC75 Specifications Page 93

  • Download
  • Add to my manuals
  • Print
  • Page
    / 120
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 92
AC75 Hardware Interface Description
Strictly confidential / Preliminary
s
AC75_HD_V00.202 Page 93 of 120 27.04.2006
5.6 Power Supply Ratings
Table 27: Power supply ratings
Parameter Description Conditions Min Typ Max Unit
Supply voltage Directly measured at reference point
TP BATT+ and TP GND, see chapter
3.2.2
Voltage must stay within the min/max
values, including voltage drop, ripple,
spikes.
3.3 3.8 4.5 V
Voltage drop during
transmit burst
Normal condition, power control level
for P
out max
400 mV
BATT+
Voltage ripple Normal condition, power control level
for P
out max
@ f<200kHz
@ f>200kHz
50
2
mV
mV
I
VDDLP
RTC Backup @ BATT+ = 0V 25 µA OFF State
supply current
POWER DOWN mode
7
50 100 µA
SLEEP mode @ DRX = 9 3.7 mA
SLEEP mode @ DRX = 5 4.6 mA
SLEEP mode @ DRX = 2 7.0 mA
I
BATT+
Average standby
supply current
8
IDLE mode @ DRX = 2 28 mA
7
Measured after module INIT (switch ON the module and following switch OFF); applied voltage on BATT+ (w/o
INIT) show increased POWER DOWN supply current.
8
Additional conditions:
- SLEEP mode measurements started 3 minutes after switch ON the module
- Averaging times: SLEEP mode - 3 minutes; IDLE mode - 1.5 minutes
- Communication tester settings: no neighbor cells, no cell reselection
- USB interface disabled
Page view 92