AC65/AC75 Hardware Interface Description
Confidential / Preliminary
s
AC65/AC75_hd_v00.372 Page 25 of 118 2006-08-03
Airplane mode Airplane mode shuts down the radio part of the module, causes the module to
log off from the GSM/GPRS network and disables all AT commands whose
execution requires a radio connection.
Airplane mode can be controlled by using the AT commands AT^SCFG and
AT+CALA:
With AT^SCFG=MEopMode/Airplane/OnStart the module can be configured
to enter the Airplane mode each time when switched on or reset.
The parameter AT^SCFG=MEopMode/Airplane can be used to switch back
and forth between Normal mode and Airplane mode any time during
operation.
Setting an alarm time with AT+CALA followed by AT^SMSO wakes the
module up into Airplane mode at the scheduled time.
Charge-only mode Limited operation for battery powered applications. Enables charging while
module is detached from GSM network. Limited number of AT commands is
accessible. Charge-only mode applies when the charger is connected if the
module was powered down with AT^SMSO.
Charge mode
during normal
operation
Normal operation (SLEEP, IDLE, TALK, GPRS/EGPRS IDLE, GPRS/EGPRS
DATA) and charging running in parallel. Charge mode changes to Charge-only
mode when the module is powered down before charging has been completed.
See Table 11 for the various options proceeding from one mode to another.