Preface 1Introduction 2Network Topologies 3Product Characteristics 4 5Diagnostics over Industrial Ethernet 6PROFINET IO Functionality 7Notes on
Introduction 2.1 Introduction Warning When used under hazardous conditions (zone 2), the devices of the SCALANCE X-100 and SCALANCE X-200 product l
Diagnostics over Industrial Ethernet 6.2 Web Based Management (WBM) If you click on an entry in the Port column, the Packet Type Statistics graphic
Diagnostics over Industrial Ethernet 6.2 Web Based Management (WBM) Figure 6-28 "Packet Error Statistics" Dialog The following errors
PROFINET IO Functionality 77.1 Configuring with PROFINET IO Using PROFINET IO One option for diagnostics, parameter assignment, and generation of al
PROFINET IO Functionality 7.1 Configuring with PROFINET IO Including the SCALANCE X-200 To include the individual switches as PN IO devices, the dev
PROFINET IO Functionality 7.1 Configuring with PROFINET IO Figure 7-3 Inserting a SCALANCE X208 1. Click on the "(1)SCALANCE" icon s
PROFINET IO Functionality 7.1 Configuring with PROFINET IO Figure 7-4 Setting Global Parameters Industrial Ethernet SCALANCE X-100 and SCALANCE
PROFINET IO Functionality 7.1 Configuring with PROFINET IO Figure 7-5 Setting Specific Parameters 1. In HW Config, open the Properties - SCALAN
PROFINET IO Functionality 7.1 Configuring with PROFINET IO Figure 7-6 Assigning the Device Name 1. Save and compile the hardware configuration.
PROFINET IO Functionality 7.1 Configuring with PROFINET IO Figure 7-7 Assigning the Device Name Industrial Ethernet SCALANCE X-100 and SCALANCE
Network Topologies 33.1 Network Topologies Switching technology allows extensive networks to be set up with numerous nodes and simplifies network ex
PROFINET IO Functionality 7.1 Configuring with PROFINET IO Figure 7-8 Assign Device Name Dialog If you use more than one IO device, the Assign Dev
PROFINET IO Functionality 7.1 Configuring with PROFINET IO Figure 7-9 Assign Device Name Dialog for Further Devices After assigning the name, th
Notes on the CE Mark 88.1 Notes on the CE Mark Product Name: SIMATIC NET SCALANCE X108 6GK5 108-0BA00-2AA3 SIMATIC NET SCALANCE X208 6GK5 208-
Notes on the CE Mark 8.1 Notes on the CE Mark Postfach 4848 D-90327 Nürnberg Notes for the Manufacturers of Machines This product is not a machine i
References 99.1 References Sources of Information and Other Documentation 1. SIMATIC NET Industrial Twisted Pair and Fiber-Optic Networks, Order n
Dimension Drawings 1010.1 Dimension Drawing Figure 10-1 Diemension Drawing SCALANCE X108, X208, X206-1, X204-2 Industrial Ethernet SCALANCE X-10
Dimension Drawings 10.1 Dimension Drawing Figure 10-2 Dimension Drawing SCALANCE X208PRO Industrial Ethernet SCALANCE X-100 and SCALANCE X-200
Index A M Autonegotiation, 4-3, 4-10, 4-19, 4-28, 4-38 MDI /MDIX Autocrossover Function, 4-3, 4-10, 4-19, 4-28, 4-38 B N BFOC socket ST socket, 4-2
Network Topologies 3.1 Network Topologies Star Topology Figure 3-2 Electrical Star Topology, Example with SCALANCE X108 Figure 3-3 Optical Sta
Index SCALANCE X204-2, 4-39 SCALANCE X206-1, 4-29 SCALANCE X208, 4-11 SCALANCE X208PRO, 4-20 Primary Setup Tool, 6-1 PROFINET IO (PN IO), 6-8 S Sign
Index Industrial Ethernet SCALANCE X-100 and SCALANCE X-200 Product Line Commissioning Manual, 1, Index-3
Network Topologies 3.1 Network Topologies Ring Topology Figure 3-4 Ring Topology, Example with SCALANCE X204-2 and SCALANCE X-400 as Redundancy
Product Characteristics 44.1 SCALANCE X108 4.1.1 Components of the SCALANCE X108 Product What ships with the SCALANCE X108? • SCALANCE X108 device
Product Characteristics 4.1 SCALANCE X108 Warning If the SCALANCE X108 device is operated in ambient temperatures between 65°C and 70°C, the tempe
Product Characteristics 4.1 SCALANCE X108 4.1.4 SCALANCE X108 TP Ports Connector Pinout On the SCALANCE X108, the twisted-pair ports are implemen
Product Characteristics 4.1 SCALANCE X108 4.1.5 SCALANCE X108 Power Supply and Signaling Contact Power Supply The power supply is connected using a
Product Characteristics 4.1 SCALANCE X108 When the device is turned off, the signaling contact is always activated (open). Figure 4-3 Signaling
Safety Guidelines This manual contains notices which you should observe to ensure your own personal safety as well as to avoid property damage. T
Product Characteristics 4.1 SCALANCE X108 Power indicator (green LED) The status of the power supply is indicated by two green LEDs: Status Meanin
Product Characteristics 4.1 SCALANCE X108 cord Aging time Aging time 5 minutes Permitted Environmental Conditions / EMC Operating temperature
Product Characteristics 4.2 SCALANCE X208 Note The number of connected SCALANCE X Industrial Ethernet Switches influences the frame propagation tim
Product Characteristics 4.2 SCALANCE X208 Warning If the SCALANCE X208 device is operated in ambient temperatures between 65°C and 70°C, the te
Product Characteristics 4.2 SCALANCE X208 4.2.4 SCALANCE X208 TP Ports Connector Pinout On the SCALANCE X208, the TP ports are implemented as RJ-45
Product Characteristics 4.2 SCALANCE X208 4.2.5 SCALANCE X208 Power Supply and Signaling Contact Power Supply The power supply is connected using
Product Characteristics 4.2 SCALANCE X208 Figure 4-6 SCALANCE X208 Signaling Contact The following errors/faults can be signaled by the signaling
Product Characteristics 4.2 SCALANCE X208 4.2.7 C-PLUG Configuration Memory Area of Application The C-PLUG is an exchangeable medium for storage
Product Characteristics 4.2 SCALANCE X208 Notice The C-PLUG may only be inserted or removed when the power is off! Removing the C-PLUG It is only
Product Characteristics 4.2 SCALANCE X208 Device startup, the LED is lit for approx. 6s. Ports 1 through 8 LED flash yellow Setting or display of
Table of contents 1 Preface ...
Product Characteristics 4.2 SCALANCE X208 or 0 - 75 m IE FC marine/trailing cable + 10 m TP cord Aging time Aging time 5 minutes Permitted Enviro
Product Characteristics 4.3 SCALANCE X208PRO C-PLUG 6GK1 900-0AB00 Note The number of connected SCALANCE X Industrial Ethernet Switches influen
Product Characteristics 4.3 SCALANCE X208PRO Warning If the SCALANCE X208PRO device is operated in ambient temperatures between 65°C and 70°C, t
Product Characteristics 4.3 SCALANCE X208PRO 4.3.4 SCALANCE X208PRO TP Ports Connector Pinout On the SCALANCE X208PRO, the TP ports are implement
Product Characteristics 4.3 SCALANCE X208PRO 4.3.5 SCALANCE X208PRO Power Supply and Signaling Contact Power Supply The power supply is connected o
Product Characteristics 4.3 SCALANCE X208PRO The following errors/faults can be signaled by the signaling contact: • The failure of a link at a m
Product Characteristics 4.3 SCALANCE X208PRO Inserting in the C-PLUG Slot The C-PLUG is not supplied with the devices of the SCALANCE X-200 product
Product Characteristics 4.3 SCALANCE X208PRO Port status indicator (green/yellow LEDs) The status of the ports is indicated by eight two-color LED
Product Characteristics 4.3 SCALANCE X208PRO connector Aging time Aging time 5 minutes Permitted Environmental Conditions / EMC Operating tempera
Product Characteristics 4.4 SCALANCE X206-1 IP67 push pull connector 09 45 145 1100 Can be ordered directly from: HARTING Deutschland GmbH &
Table of contents 4.4.7 SCALANCE X206-1 Button...
Product Characteristics 4.4 SCALANCE X206-1 4.4.2 Unpacking and Checking Unpacking, Checking 1. Make sure that the package is complete. 2. Check
Product Characteristics 4.4 SCALANCE X206-1 Figure 4-10 SCALANCE X206-1 4.4.4 SCALANCE X206-1 TP Ports Connector Pinout On the SCALANCE X206-1,
Product Characteristics 4.4 SCALANCE X206-1 autonegotiation, two components connected to a link segment can exchange parameters and set themselves t
Product Characteristics 4.4 SCALANCE X206-1 Range The maximum transmission range (segment length) is 3 km. Connectors The cables are connected ove
Product Characteristics 4.4 SCALANCE X206-1 Figure 4-12 SCALANCE X206-1 Signaling Contact The following errors/faults can be signaled by the sign
Product Characteristics 4.4 SCALANCE X206-1 4.4.8 C-PLUG Configuration Memory Area of Application The C-PLUG is an exchangeable medium for storag
Product Characteristics 4.4 SCALANCE X206-1 Notice The C-PLUG may only be inserted or removed when the power is off! Removing the C-PLUG It is onl
Product Characteristics 4.4 SCALANCE X206-1 Device startup, the LED is lit for approx. 6s. Ports 1 through 8 LED flash yellow Setting or display
Product Characteristics 4.4 SCALANCE X206-1 0 – 85 m 0 -3,000 m IE FC marine/trailing cable with IE FC RJ-45 plug 180 or IE FC marine/trailing
Product Characteristics 4.5 SCALANCE X204-2 "Industrial Ethernet TP and Fiber Optic Networks" manual 6GK1970-1BA10-0AA0 IE FC Stripping
Table of contents 6.2.4.16 The "Agent Trap Configuration" WBM Menu ...
Product Characteristics 4.5 SCALANCE X204-2 4.5.2 Unpacking and Checking Unpacking, Checking 1. Make sure that the package is complete. 2. Check
Product Characteristics 4.5 SCALANCE X204-2 Figure 4-13 SCALANCE X204-2 4.5.4 SCALANCE X204-2 TP Ports Connector Pinout On the SCALANCE X204-2,
Product Characteristics 4.5 SCALANCE X204-2 port of a partner device allowing automatic configuration of different types of device. With autonegotia
Product Characteristics 4.5 SCALANCE X204-2 Range The maximum transmission range (segment length) is 3 km. Connectors The cables are connected ove
Product Characteristics 4.5 SCALANCE X204-2 Signaling Contact The signaling contact is connected to a 2-pin plug-in terminal block. The signaling co
Product Characteristics 4.5 SCALANCE X204-2 4.5.8 C-PLUG Configuration Memory Area of Application The C-PLUG is an exchangeable medium for storag
Product Characteristics 4.5 SCALANCE X204-2 Notice The C-PLUG may only be inserted or removed when the power is off! Removing the C-PLUG It is onl
Product Characteristics 4.5 SCALANCE X204-2 Device startup, the LED is lit for approx. 6s. Ports 1 through 8 LED flash yellow Setting or display
Product Characteristics 4.5 SCALANCE X204-2 0 – 85 m 0 -3,000 m IE FC marine/trailing cable with IE FC RJ-45 plug 180 or IE FC marine/trailing
Product Characteristics 4.5 SCALANCE X204-2 IE FC blade cassettes 6GK1901-1GB00 IE FC TP standard cable 6XV1840 2AH10 IE FC TP trailing cable 6
Installation and Maintenance 55.1 Installation Types of Installation The Industrial Ethernet switches of the SCALANCE X-100 and X-200 product lines
Installation and Maintenance 5.2 Installation on a DIN Rail Figure 5-1 Installation of a SCALANCE X-100 and/or X-200 on a 35 mm Standard Rail Unin
Installation and Maintenance 5.3 Installation on a Standard Rail Figure 5-2 Removing a SCALANCE X-100 and/or X-200 from a 35 mm Standard Rail 5.
Installation and Maintenance 5.4 Wall Mounting Figure 5-3 Installation of a SCALANCE X-100 and/or X-200 on a SIMATIC S7-300 Standard Rail Uninstal
Installation and Maintenance 5.5 Grounding Note The wall mounting must be capable of supporting at least four times the weight of the device. 5.
Installation and Maintenance 5.6 Fitting the IE FC RJ-45 Plug 180 Figure 5-4 IE FC RJ-45 Plug 180 Inserting the IE FC RJ-45 Plug 180 1. Insert th
Installation and Maintenance 5.6 Fitting the IE FC RJ-45 Plug 180 Note This does not apply to the SCALANCE X208PRO device Removing the IE FC RJ-
Installation and Maintenance 5.7 Maintenance Figure 5-7 Releasing the RJ-45 Plug with a Screwdriver 5.7 Maintenance Maintenance If a fault develo
Diagnostics over Industrial Ethernet 6 The diagnostics over Industrial Ethernet described in the following section is possible only with devices of t
Preface 11.1 Preface Purpose of the Commissioning Manual This commissioning manual supports you when commissioning networks with the devices of the
Diagnostics over Industrial Ethernet 6.1 Configuration with the Primary Setup Tool 1. Double-click on the setup.exe file name in the Windows Explor
Diagnostics over Industrial Ethernet 6.1 Configuration with the Primary Setup Tool Figure 6-1 Properties of Local Area Connection-1 6.1.4 Inst
Diagnostics over Industrial Ethernet 6.1 Configuration with the Primary Setup Tool 4. Click the Install button in the General tab . 5. In the Netw
Diagnostics over Industrial Ethernet 6.1 Configuration with the Primary Setup Tool Procedure Follow the steps below to configure a device: 1. Cli
Diagnostics over Industrial Ethernet 6.1 Configuration with the Primary Setup Tool Figure 6-2 Configuring a Module Downloading Configuration Data
Diagnostics over Industrial Ethernet 6.1 Configuration with the Primary Setup Tool Figure 6-3 Downloading the Module Starting Web Based Managem
Diagnostics over Industrial Ethernet 6.2 Web Based Management (WBM) Assigning a PN IO Device Name You can assign a PN IO device name to PROFINET IO-
Diagnostics over Industrial Ethernet 6.2 Web Based Management (WBM) Note Firewall When using a firewall, access to the following ports must be po
Diagnostics over Industrial Ethernet 6.2 Web Based Management (WBM) Figure 6-5 Logon Screenshot 6.2.4 WBM Menus 6.2.4.1 Management Menus - The S
Diagnostics over Industrial Ethernet 6.2 Web Based Management (WBM) Figure 6-6 Start Dialog 6.2.4.2 The "System Configuration" WBM Me
Preface 1.1 Preface Standards and Approvals The devices of the SCALANCE X-100 and X-200 product lines meet the requirements for the CE mark. You wil
Diagnostics over Industrial Ethernet 6.2 Web Based Management (WBM) Figure 6-7 "System Configuration" Dialog System Up Time Text Box The
Diagnostics over Industrial Ethernet 6.2 Web Based Management (WBM) 6.2.4.3 The "System Restart & Defaults" WBM Menu System Restart
Diagnostics over Industrial Ethernet 6.2 Web Based Management (WBM) • System contact There is no automatic restart, the parameters take effect imme
Diagnostics over Industrial Ethernet 6.2 Web Based Management (WBM) 6.2.4.5 The "System Save & Load TFTP" WBM Menu System Save &
Diagnostics over Industrial Ethernet 6.2 Web Based Management (WBM) 6.2.4.6 The "System Version Numbers" WBM Menu System Version Numbers
Diagnostics over Industrial Ethernet 6.2 Web Based Management (WBM) 6.2.4.7 The "System Passwords" WBM Menu System Passwords In this di
Diagnostics over Industrial Ethernet 6.2 Web Based Management (WBM) Figure 6-13 "Status" Dialog Power Text Box This displays how the pow
Diagnostics over Industrial Ethernet 6.2 Web Based Management (WBM) 6.2.4.10 The "Ring Redundancy" WBM Menu Ring Redundancy This page a
Diagnostics over Industrial Ethernet 6.2 Web Based Management (WBM) 6.2.4.11 The "C-PLUG Information" WBM Menu C-PLUG Information This d
Diagnostics over Industrial Ethernet 6.2 Web Based Management (WBM) Figure 6-17 "Agent Configuration" Dialog IP Address Text Box The I
Introduction 22.1 Introduction This chapter provides you with an overview of the functions of the Industrial Ethernet switches of the SCALANCE X-100
Diagnostics over Industrial Ethernet 6.2 Web Based Management (WBM) Figure 6-18 "Agent Event Configuration" Dialog You can configure the
Diagnostics over Industrial Ethernet 6.2 Web Based Management (WBM) 6.2.4.14 The "Agent E-Mail Configuration" WBM Menu Agent E-Mail Con
Diagnostics over Industrial Ethernet 6.2 Web Based Management (WBM) Here, you enter the IP address of the SMTP server over which the E-mail is sent.
Diagnostics over Industrial Ethernet 6.2 Web Based Management (WBM) Displays the user name for write access to SNMP variables. Here, changes can o
Diagnostics over Industrial Ethernet 6.2 Web Based Management (WBM) 6.2.4.17 The "Switch Configuration (Port Mirroring)" WBM Menu Port Mi
Diagnostics over Industrial Ethernet 6.2 Web Based Management (WBM) Figure 6-23 "Switch Ports Status" Dialog Type Information Box Dis
Diagnostics over Industrial Ethernet 6.2 Web Based Management (WBM) 6.2.4.19 The "Switch Port Diagnostics" WBM Menu Switch Port Diagnosti
Diagnostics over Industrial Ethernet 6.2 Web Based Management (WBM) Displays the pair of cores in the cable. Pairs 4-5 and 7-8 are not used. Statu
Diagnostics over Industrial Ethernet 6.2 Web Based Management (WBM) Octets In Information Box Displays the number of received bytes. Octets Out Info
Diagnostics over Industrial Ethernet 6.2 Web Based Management (WBM) Figure 6-26 "Packet Size Statistics" Dialog 64 Information Box Dis
Comments to this Manuals