SITRANS F M MAGFLO
®®
®®
®
Electromagnetic flowmeters
Sensor types MAG 1100, MAG 3100, MAG 5100 W
Transmitter types MAG 5000, MAG 6000
s
[ ]
Technical Documentation (handbooks, instructions, manuals etc.) on the complete product
range SITRANS F can be found on the internet/intranet on the following links:
English:
http://www4.ad.siemens.de/WW/view/en/10806951/133300
Page view 0
1 2 3 4 5 6 ... 79 80

Summary of Contents

Page 1 - SITRANS F M MAGFLO

HandbookEdition 04/2005 - Revision 04Order no.: FDK-521H0723SFIDK.PS.027.W4.02SITRANS F M MAGFLO®®®®®Electromagnetic flowmetersSensor types MAG 1100,

Page 2

10 SFIDK.PS.027.W4.022. Technical dataTechnical dataSITRANS F M MAGFLO®Type Sensor with flanges Sensor with flanges Sensor with flangesNominal sizemm

Page 3 - SFIDK.PS.027.W4.02

11SITRANS F M MAGFLO®SFIDK.PS.027.W4.022. Technical dataTechnical dataFlangesStandardDN 15-50: PN 40 DN 25-50: PN 40EN 1092-1:20011) DN 65-150: PN 1

Page 4

12 SFIDK.PS.027.W4.022. Technical dataTechnical dataSITRANS F M MAGFLO®Type Sensor with flangesDesign Straight Coned 1 DN reduction StraightNominal s

Page 5

13SITRANS F M MAGFLO®SFIDK.PS.027.W4.022. Technical dataTechnical dataCurrent outputCurrent 0-20 mA, 4-20 mA or 4-20 mA + alarmLoad < 800 ohmTime

Page 6

14 SFIDK.PS.027.W4.022. Technical dataTechnical dataSITRANS F M MAGFLO®Current outputCurrent 0-20 mA, 4-20 mA or 4-20 mA + alarmLoad < 800 ohmTime

Page 7

15SITRANS F M MAGFLO®SFIDK.PS.027.W4.022. Technical dataTechnical dataSafety barrier & cleaning unitApplication As combined unit with MAG 6000 o

Page 8 - MAG 1100 Ex & Ex-d

16 SFIDK.PS.027.W4.022. Technical dataTechnical dataSITRANS F M MAGFLO®MAG 5000 or MAG 6000 used with MAG 3100 W or MAG 1100 PFA2.6Meter uncertainty*

Page 9

17SITRANS F M MAGFLO®SFIDK.PS.027.W4.022. Technical dataTechnical data2.7Output characteristicsMAG 5000 and MAG 6000Output characteristics Bidirecti

Page 10 - Technical data

18 SFIDK.PS.027.W4.022. Technical dataTechnical dataSITRANS F M MAGFLO®Coil cable Electrode cableBasic data No. of conductors 2 3Min. sqr. area 0.5 m

Page 11 - (continued)

19SITRANS F M MAGFLO®3. Project guidanceSFIDK.PS.027.W4.02Project guidance3. Project guidance3.1Sizing table(DN 2 to DN 2000)The table shows the re

Page 12

SFIDK.PS.027.W4.02SITRANS F M MAGFLO®Siemens Flow Instrumentsrange of electromagneticflowmeters2MAG 1100 MAG 1100 MAG 3100 MAG 3100 W MAG 5100 WFOODS

Page 13 - Optional

20SITRANS F M MAGFLO®3. Project guidanceSFIDK.PS.027.W4.02Project guidance3.2.1Minimum conductivityApplications Min. conductivityCompact/remote DN 2

Page 14

21SITRANS F M MAGFLO®3. Project guidanceSFIDK.PS.027.W4.02Project guidanceThe sensor must be mounted as shown in theupper figure. Do not mount the s

Page 15

22SITRANS F M MAGFLO®3. Project guidanceSFIDK.PS.027.W4.02Project guidanceTo achieve accurate flow measurement it is es-sential to have straight leng

Page 16

23SITRANS F M MAGFLO®3. Project guidanceSFIDK.PS.027.W4.02Project guidanceThe sensor and transmitter can be installedeither compact or remote.With

Page 17

24SITRANS F M MAGFLO®3. Project guidanceSFIDK.PS.027.W4.02Project guidanceThe Siemens Flow Instruments cleaning unit can be used with MAG 5000 or 600

Page 18 - Cable specification

25SITRANS F M MAGFLO®3. Project guidanceSFIDK.PS.027.W4.02Project guidanceA transmitter can be supplied in a version testedand approved for custody

Page 19 - Project guidance

26SITRANS F M MAGFLO®3. Project guidanceSFIDK.PS.027.W4.02Project guidance3.7 Ex survey accordingto Directive 94/9/EC(ATEX)Applies to instruments use

Page 20 - (Without DC cleaning unit)

27SITRANS F M MAGFLO®3. Project guidanceSFIDK.PS.027.W4.02Project guidanceSITRANS F M MAGFLO® sensors carry the following approvalsMAG 1100 Ex for m

Page 21

28SITRANS F M MAGFLO®SFIDK.PS.027.W4.024. Dimensions and weightD & WMAG 1100, compact/separate4. Dimensions andweight4.1Sensor MAG 1100DN A1)B1)A

Page 22

29SITRANS F M MAGFLO®SFIDK.PS.027.W4.024. Dimensions and weightD & W4.2Sensor MAG 1100 FOODMAG 1100 FOOD, compact and separateDN L A1)A1B1)B1DDi

Page 23 - Vertical installation

3SITRANS F M MAGFLO®SFIDK.PS.027.W4.021.1 Product introduction ...

Page 24 - DC-cleaning

30SITRANS F M MAGFLO®SFIDK.PS.027.W4.024. Dimensions and weightD & WAccessoriesMAG 1100 FOODWeld-in typeDIN 11850 DS/ISO 2037 SMS 3008 BS4825-1 T

Page 25

31SITRANS F M MAGFLO®SFIDK.PS.027.W4.024. Dimensions and weightD & WAccessoriesMAG 1100 FOOD(continued)Threaded typeDIN 11851Di Do[mm] [mm] [mm]

Page 26 - with gases

32SITRANS F M MAGFLO®SFIDK.PS.027.W4.024. Dimensions and weightD & W350 14" 362 14.3 550 21.7 550 21.7 N/A N/A 550 21.7 N/A N/A400 16"

Page 27

33SITRANS F M MAGFLO®SFIDK.PS.027.W4.024. Dimensions and weightD & Wmm inch kgs lbs kgs lbs kgs lbs kgs lbs kgs lbs25 1" N/A N/A N/A N/A 4

Page 28 - D & W

34SITRANS F M MAGFLO®SFIDK.PS.027.W4.024. Dimensions and weightD & WDN A1) A1BD1L2)AS TC 3)TE 3)2129 E, AWWAAS 4087 C-207PN PN PN PN PN Class Cla

Page 29 - Built-in length

35SITRANS F M MAGFLO®SFIDK.PS.027.W4.024. Dimensions and weightD & W4.5TransmitterTransmitter installed in compact modeWeight: MAG 6000 and MAG

Page 30 - MAG 1100 FOOD

36SITRANS F M MAGFLO®SFIDK.PS.027.W4.024. Dimensions and weightD & WWall mounting box 21 TEWeight excl. transmitter: 2.3 kgWall mounting box 42 T

Page 31 - (continued)

37SITRANS F M MAGFLO®SFIDK.PS.027.W4.024. Dimensions and weightD & WBack of panel unit 21 TEBack of panel unit 42 TEWeight: 0.9 kgWeight: 0.7 kg

Page 32 - Will be discontinued

38 SFIDK.PS.027.W4.02SITRANS F M MAGFLO®5. Installation of sensorSensorTo obtain optimum results from the measuring system, the chassis body of the s

Page 33 - 4. Dimensions and weight

39SFIDK.PS.027.W4.02SITRANS F M MAGFLO®5. Installation of sensorSensorMAG 3100(PTFE liner)Electrically conductive pipingUse an earth straps on one s

Page 34

4SITRANS F M MAGFLO®SFIDK.PS.027.W4.02All SITRANS F M MAGFLO® electromagnetic flowmeters feature a unique SENSORPROM®memory unit which stores sensor c

Page 35 - Earthing/protection flange

40SITRANS F M MAGFLO®SFIDK.PS.027.W4.026. Installation of transmitterInstallation of transmitter6. Installation oftransmitter6.1Compact installationM

Page 36 - Panel front unit 21 TE

SITRANS F M MAGFLO®SFIDK.PS.027.W4.026. Installation of transmitterInstallation of transmitter411. Use a screw driver to remove the outerframe.2. Loo

Page 37 - Panel front unit 42 TE

42SITRANS F M MAGFLO®SFIDK.PS.027.W4.026. Installation of transmitterInstallation of transmitterLocate the add-on module in the bottom of theMAG 6000

Page 38 - (except PTFE liner)

SITRANS F M MAGFLO®SFIDK.PS.027.W4.026. Installation of transmitterInstallation of transmitter436.2.3Remote installation -Wall mountingMAG 6000Mount

Page 39 - Isolated sensor:

44SITRANS F M MAGFLO®SFIDK.PS.027.W4.026. Installation of transmitterInstallation of transmitter6.2.3Remote installation -Wall mounting(continued)Cau

Page 40

SITRANS F M MAGFLO®SFIDK.PS.027.W4.026. Installation of transmitterInstallation of transmitter456.2.4Remote installation -Transmitter in 19" ins

Page 41 - Turning the transmitter

46SITRANS F M MAGFLO®SFIDK.PS.027.W4.026. Installation of transmitterInstallation of transmitterLocate the add-on module in the bottom of theMAG 6000

Page 42 - At the sensor

SITRANS F M MAGFLO®SFIDK.PS.027.W4.026. Installation of transmitterInstallation of transmitter476.2.6Installation in IP 66 wallmounting enclosure1. M

Page 43 - Horizontal pipe mounting

48SITRANS F M MAGFLO®SFIDK.PS.027.W4.026. Installation of transmitterInstallation of transmitter6.2.7Installation in IP 65 panelmounting enclosure(fr

Page 44

SITRANS F M MAGFLO®SFIDK.PS.027.W4.026. Installation of transmitterInstallation of transmitter496.2.8Installation into the backof a panel1. Mount the

Page 45

5SITRANS F M MAGFLO®SFIDK.PS.027.W4.021. Product introductionUi = When an electrical conductor of length L is moved at velocity v, perpendicular to

Page 46

50SITRANS F M MAGFLO®SFIDK.PS.027.W4.026. Installation of transmitterInstallation of transmitter6.3TransmitterSafety barrier1. Fit the SENSORPROM® me

Page 47

SITRANS F M MAGFLO®SFIDK.PS.027.W4.026. Installation of transmitterInstallation of transmitter516.4TransmitterCleaning unit1. Fit the SENSORPROM® mem

Page 48

52SITRANS F M MAGFLO®SFIDK.PS.027.W4.027. Electrical connectionE. c.7. Electrical connection7.1TransmitterMAG 5000 and MAG 6000connection diagramNot

Page 49

53SITRANS F M MAGFLO®7. Electrical connectionSFIDK.PS.027.W4.02E. c.7.2Wiring diagram fortransmitter and sensorCompact installationCompactRemote IP

Page 50

54SITRANS F M MAGFLO®SFIDK.PS.027.W4.027. Electrical connectionE. c.19” IP 20 version19” IP 66 version19” IP 20 versionEEx (ia/ib) DN ≤ ≤ ≤ ≤ ≤ 300

Page 51

55SITRANS F M MAGFLO®7. Electrical connectionSFIDK.PS.027.W4.02E. c.19” IP 20 versionEEx e (ib) DN ≥≥≥≥≥ 35019” IP 66 versionEEx (ia/ib) DN ≤ ≤ ≤ ≤

Page 52

56SITRANS F M MAGFLO®SFIDK.PS.027.W4.027. Electrical connectionE. c.19” IP 20 version withcleaning19” IP 66 version withcleaning

Page 53 - Remote installation

57SFIDK.PS.027.W4.02SITRANS F M MAGFLO®8. CommissioningCommissioningCommunication mode Basic settings Operator activeService mode Output Operator in

Page 54 - EEx (ia/ib) DN

58 SFIDK.PS.027.W4.02SITRANS F M MAGFLO®8. CommissioningCommissioning8.2Menu build-upThe menu structure of a specific transmitter type is shown in a

Page 55 - 7. Electrical connection

59SFIDK.PS.027.W4.02SITRANS F M MAGFLO®8. CommissioningCommissioning8.3.1 MAG 5000 and MAG 6000Menu overview

Page 56 - 19” IP 66 version with

6SITRANS F M MAGFLO®SFIDK.PS.027.W4.021. Product introduction1.3Pressure EquipmentDirective 97/23ECsFlange PN 6 PN 10 PN 16 PN 25 PN 40 PN 64 PN 100

Page 57 - Commissioning

60 SFIDK.PS.027.W4.02SITRANS F M MAGFLO®8. CommissioningCommissioning8.3.2 MAG 5000 CT and MAG 6000 CTMenu overview

Page 58 - Setup mode

61SFIDK.PS.027.W4.02SITRANS F M MAGFLO®8. CommissioningCommissioning8.4.1Basic settingsMenu detailComma for flow rate, totalizer 1 and totalizer 2 c

Page 59 - 8.3.1 MAG 5000 and MAG 6000

62 SFIDK.PS.027.W4.02SITRANS F M MAGFLO®8. CommissioningCommissioning8.4.3Digital and relay outputsError levelError number8.4.2OutputsDigital outputF

Page 60

63SFIDK.PS.027.W4.02SITRANS F M MAGFLO®8. CommissioningCommissioningMenu detailLimit/directionLimit switches are available for both digital as well

Page 61 - Empty pipe cut off

64 SFIDK.PS.027.W4.02SITRANS F M MAGFLO®8. CommissioningCommissioningMenu detail8.4.6Sensor characteristics8.4.7Reset modeIf “SENSORPROM notinstalled

Page 62 - 4 - 20 mA + alarm:

65SFIDK.PS.027.W4.02SITRANS F M MAGFLO®8. CommissioningCommissioning8.4.8Service modeAll previous settings are reinitialised when service mode is ex

Page 63 - Non CT versions only

66 SFIDK.PS.027.W4.02SITRANS F M MAGFLO®8. CommissioningCommissioningMenu setup8.4.9Operator menu setupThe upper line is always active and can never

Page 64 - If “SENSORPROM not

67SFIDK.PS.027.W4.02SITRANS F M MAGFLO®8. CommissioningCommissioning8.4.10Product identitySoftware version of add-on module is only available if the

Page 65

68 SFIDK.PS.027.W4.02SITRANS F M MAGFLO®8. CommissioningCommissioning8.4.12Language modeMenu detail8.4.13HART®®®®® communicationMAG 5000 HART or asad

Page 66

69SFIDK.PS.027.W4.02SITRANS F M MAGFLO®8. CommissioningCommissioning8.5.3Batch(Only available onMAG 6000)A batch can be started, paused or stopped f

Page 67

7SITRANS F M MAGFLO®SFIDK.PS.027.W4.02MAG 3100 high temperature PTFEFlange PN 6 PN 10 PN 16 PN 25 PN 40 150 lb 300 lbmm15 N/A N/A N/A N/A SEP SEP SEP

Page 68

70 SFIDK.PS.027.W4.02SITRANS F M MAGFLO®8. CommissioningCommissioning8.6.1Settings availableParameter Factory settings Settings availablePasswordDefa

Page 69 - Batch cycle counter reset

71SFIDK.PS.027.W4.02SITRANS F M MAGFLO®8. CommissioningCommissioningDN Qmax.MAG 5100 W MAG 1100,3100, 3100 W Volume/ Pulse Totalizermm [inches] fac.

Page 70

72 SFIDK.PS.027.W4.02SITRANS F M MAGFLO®8. CommissioningCommissioningInternal totalizersDepending on type of approval it is possible to reset the int

Page 71

73SFIDK.PS.027.W4.02SITRANS F M MAGFLO®8. CommissioningCommissioningError systemThe transmitter system is equipped with an error and status log syst

Page 72 - Other liquids

74 SFIDK.PS.027.W4.02SITRANS F M MAGFLO®8. CommissioningCommissioningError Error text #Comment Outputs InputNo. Remedy text status status1 I1 - Power

Page 73

75SFIDK.PS.027.W4.02SITRANS F M MAGFLO®9. ServiceCommissioning9. ServicePower on transmitter,display light onYESNONOCheck cables/connectionsCheck c

Page 74 - List of error numbers

76 SFIDK.PS.027.W4.02SITRANS F M MAGFLO®9. ServiceCommissioning9.2Trouble shootingMAG transmitterSymptom Output Error Cause Remedysignals codeEmpty d

Page 75

77SFIDK.PS.027.W4.02SITRANS F M MAGFLO®9. ServiceCommissioningATTENTION!If there is leakage from MAG 1100/3100/3100 W or MAG 5100 W and the unit has

Page 76

78 SFIDK.PS.027.W4.02SITRANS F M MAGFLO®9. ServiceCommissioning9.4Coil resistanceCoil resistanceMAG 1100 MAG 3100 MAG 3100 W MAG 5100 WDN Resistance

Page 77

SFIDK.PS.027.W4.02SITRANS F M MAGFLO®7910. Ordering Please look on our homepage http://www.siemens.com/flow under "Product Selector".Order-

Page 78

8 SFIDK.PS.027.W4.022. Technical dataTechnical dataSITRANS F M MAGFLO®Type Flangeless sensor (Sandwich design)Nominal sizemmDN 2,3,6,10,15,25,40,50,6

Page 79 - 10. Ordering

We have checked the contents of this manual for agreement with the hardware andsoftware described. Since deviations cannot be precluded entirely, we c

Page 80

9SITRANS F M MAGFLO®SFIDK.PS.027.W4.022. Technical dataTechnical dataAdapter Stainless steel AISI 316 PressurePipe connection/ Adapter for direct we

Comments to this Manuals

No comments