Answers for energy. Type Vector® manual group-operated switch instruction manualInstallation operation maintenance E50001-F710-A420-X-4A00
Receiving, handling and storageLifting and movingThere are a number of methods that can be used in handling the type Vector® manual group-operated sw
InstallationInstallationInstallation instructions for the type Vector manual group-operated air switch are detailed in the following steps:1. Drill
Installation8. Remove single-point lift bracket.9. Ground the air switch unit (and surge arresters if required) using #2 or larger copper wire.
Operating handle adjustment procedureOperating handle adjustment procedureThe next series of steps address adjusting the position of the handle assem
Operational check out instructionsOperational check out instructionsOperational check out instructions for the type Vector® manual group-operated swi
Operational check out instructions 2. As the blade continues to rotate open, the interrupter lever must make full metal-to-metal c
MaintenanceMaintenanceMaintenance instructions for the type Vector® manual group-operated switch are detailed in the following steps:1. Periodical
MaintenanceTable 2: Remarks17
www.usa.siemens.com/energyPublished by and copyright © 2011:Siemens AGEnergy SectorFreyeslebenstrasse 191058 Erlangen, GermanySiemens Energy, Inc.99 B
ImportantThe information contained herein is general in nature and not intended for specific application purposes. It does not relieve the user of res
Table of contentsIntroduction 4 - 5General description 6 - 7Receiving, handling and storage 8 - 10Installation 11 - 12Operating handle adjustment proc
IntroductionIntroductionThe type Vector® manual group-operated switch is designed to meet all applicable ANSI, NEMA and IEEE standards. Successful ap
IntroductionSignal wordsThe signal words "danger," "warning" and "caution" used in this instruction manual indicate the
General descriptionIntroductionSiemens type Vector® manual group-operated air switch is precision built equipment designed to function efficiently und
General descriptionScopeThese instructions cover the installation, operation and maintenance of a Siemens type Vector® manual group-operated air swit
Receiving, handling and storageReceivingEach type Vector® manual group-operated air switch is securely blocked and braced for shipment on a pallet. I
Receiving, handling and storage3. Any visible damage must be noted on the delivery receipt and acknowledged with the driver’s signature. The damage